Streamlining the Donor Interview Process: Recommendations for Self-Administered Questionnaires: Guidance for Industry

us-fda-guidance-43970c6ad6b14c0d02dd6ba4d13a4798Streamlining the Donor Interview Process: Recommendations for Self-Administered Questionnaires: Guidance for IndustryGuidance

Administrative guidance, not enacted legislation. This captured publisher edition preserves the listed document and attachments; later developments are not independently consolidated.

Docket Number:
FDA-2002-D-0524
Issued by:
Guidance Issuing Office
Center for Biologics Evaluation and Research

Blood and plasma establishments (hereafter referred to as “blood establishments”) that collect blood and blood components intended for transfusion or for further manufacture may present donor screening questions to the donor by several methods. The blood establishment should choose the method that works best within its donor screening procedures. This guidance is intended for those blood establishments that wish to implement self-administered donor questionnaires, which allow donors to answer the pre-donation questions on their own; however, you (the blood establishment) may elect to continue to administer the donor questions by direct oral questioning. The guidance provides the recommendations of the Food and Drug Administration (FDA) for implementing self-administered donor questionnaires. In addition, the guidance describes the information the licensed blood establishments should include in a biologics license application supplement or annual report when they intend to implement self-administered questionnaires. This guidance finalizes the draft guidance of the same title dated April 2002. It also supersedes Section I.A of FDA’s memorandum dated April 23, 1992, entitled “Revised Recommendations for the Prevention of Human Immunodeficiency Virus (HIV) Transmission by Blood and Blood Products.”


Submit Comments

You can submit online or written comments on any guidance at any time (see 21 CFR 10.115(g)(5))

If unable to submit comments online, please mail written comments to:

Dockets Management
Food and Drug Administration
5630 Fishers Lane, Rm 1061
Rockville, MD 20852

All written comments should be identified with this document's docket number: FDA-2002-D-0524.

Questions?

Contact Point
Office of Communication, Outreach and Development (OCOD)
Center for Biologics Evaluation and Research
Food and Drug Administration
10903 New Hampshire Ave WO71-3128
Silver Spring, MD 20993-0002
ocod@fda.hhs.gov
(800) 835-4709
(240) 402-8010
Guidance for Industry
Streamlining the Donor Interview
Process: Recommendations for
Self-Administered Questionnaires
Additional copies of this guidance are available from the Office of Communication, Training and
Manufacturers Assistance (HFM-40), 1401 Rockville Pike, Rockville, MD 20852-1448, or by
calling 1-800-835-4709 or 301-827-1800, or from the Internet at
http://www.fda.gov/cber/guidelines.htm.
For questions on the content of the guidance contact the Division of Blood Applications, Office
of Blood Research and Review, CBER, at 301-827-3543, or by fax at 301-827-3534.
U.S. Department of Health and Human Services
Food and Drug Administration
Center for Biologics Evaluation and Research (CBER)
July 2003
Complete printed PDF page 1
Contains Nonbinding Recommendations
TABLE OF CONTENTS
I. 	INTRODUCTION............................................................................................................... 1
II. 	BACKGROUND ................................................................................................................. 1
III. 	RECOMMENDATIONS FOR IMPLEMENTING SELF-ADMINISTERED DONOR
QUESTIONNAIRES .......................................................................................................... 3
A. 	Recommendations for All Self-Administered Procedures .................................... 3
B. 	Additional Recommendations for the Use of Audio/Visual Tools ........................ 5
C. 	Additional Recommendations for Computer-Assisted Interactive Procedures.. 5
IV. 	PROCEDURES FOR SUPPLEMENTING THE BIOLOGICS LICENSE
APPLICATION TO INCLUDE THE USE OF SELF-ADMINISTERED DONOR
QUESTIONNAIRES .......................................................................................................... 6
A. 	General Submission Information ............................................................................ 6
B. 	Submission Content for All Self-Administered Procedures.................................. 7
C. 	Additional Submission Content for Computer-Assisted Interactive Procedures7
V. 	FOR MORE INFORMATION .......................................................................................... 8
VI. 	REFERENCES .................................................................................................................... 9
i
Complete printed PDF page 2
Contains Nonbinding Recommendations
GUIDANCE FOR INDUSTRY
Streamlining the Donor Interview Process:
Recommendations for Self-Administered Questionnaires
This guidance represents the Food and Drug Administration’s (FDA’s) current thinking on this
topic. It does not create or confer any rights for or on any person and does not operate to bind
FDA or the public. You can use an alternative approach if the approach satisfies the
requirements of the applicable statutes and regulations. If you want to discuss an alternative
approach, contact the appropriate FDA staff. If you cannot identify the appropriate FDA staff,
call the appropriate number listed on the title page of this guidance.
I. 	INTRODUCTION
Blood and plasma establishments (hereafter referred to as “blood establishments”) that collect
blood and blood components intended for transfusion or for further manufacture may present
donor screening questions to the donor by several methods. The blood establishment should
choose the method that works best within its donor screening procedures. This guidance is
intended for those blood establishments that wish to implement self-administered donor
questionnaires, which allow donors to answer the pre-donation questions on their own; however,
you (the blood establishment) may elect to continue to administer the donor questions by direct
oral questioning. The guidance provides the recommendations of the Food and Drug
Administration (FDA) for implementing self-administered donor questionnaires. 	In addition,
the guidance describes the information the licensed blood establishments should include in a
biologics license application supplement or annual report when they intend to implement self-
administered questionnaires. This guidance finalizes the draft guidance of the same title dated
April 2002. It also supersedes Section I.A of FDA’s memorandum dated April 23, 1992, entitled
“Revised Recommendations for the Prevention of Human Immunodeficiency Virus (HIV)
Transmission by Blood and Blood Products.”
FDA’s guidance documents, including this guidance, do not establish legally enforceable
responsibilities. Instead, guidances describe the FDA’s current thinking on a topic and should be
viewed only as recommendations, unless specific regulatory or statutory requirements are cited.
The use of the word should in FDA’s guidances means that something is suggested or
recommended, but not required.
II. 	BACKGROUND
A donor’s suitability to donate blood and blood components is determined in part by a
medical/health history/high-risk behavior interview (21 CFR 640.3 and 640.63). Blood
establishments began formal questioning of blood donors about their health in the 1950s with the
1
Complete printed PDF page 3
Contains Nonbinding Recommendations
development of the first donor screening questionnaire. Since then, the number of questions and
the amount of information captured during the questioning process has increased due to FDA
requirements and recommendations and voluntary standards, resulting in an increasingly
complex and time-consuming process. For example, we have recommended that you ask the
high-risk behavior questions by direct oral questioning (Ref. 1). This guidance updates those
recommendations to allow blood donors to self-administer the high-risk behavior questions.
Blood establishments are concerned that the current donor questionnaire process is burdensome
for the following reasons: (a) the donor questionnaire is complicated, (b) the donor interview
process makes increasing demands upon limited resources at the blood collection facilities (e.g.,
time and personnel), and (c) many donors are concerned about answering personal questions in
front of a stranger. We are committed to improving the efficiency and effectiveness of the
donation process. Consequently, we are evaluating methods to streamline the interview process
while maintaining and improving the accuracy and completeness of the information in order to
better protect the health of donors and ensure the safety, purity, and potency of blood products.
You must determine the donor’s suitability on the day of each donation (§§ 640.3(a) and
640.63(a)). Collection personnel use pre-donation screening questions to assist them in
determining donor suitability. The questions are an integral part of the donation process to help
personnel assess risks to the donor from the donation process. In addition, the questions help to
ensure product safety by addressing hazards that may not be detectable by laboratory testing and
help to ensure product purity and potency (Ref. 2).
We define the self-administered, pre-donation questionnaire as one in which the donor reads or
listens to the medical/health history questions and/or high-risk questions and documents his/her
answers. A self-administered questionnaire process allows a donor to answer the pre-donation
screening questions without direct oral questioning by collection personnel. We are not
including donor identification or demographic questions (e.g., name, address, social security
number) in this definition. You may elect to allow donors to self-administer only the
medical/health history questions, only the high-risk behavior questions, or both, as long as you
do not jeopardize donor safety and product safety, purity, and potency. There are several options
available for self-administering the donor questionnaire. These include, but are not limited to:
1. 	Questions presented on printed forms. The donor reads the questions and documents the
answers on the form. 	Your personnel review the answers.
2. 	Audio and/or video presentation of the questions. The donor reviews the questions by
listening to a recording or watching a video and documents the answers. Your personnel
review the answers.
3. 	Computer-assisted interactive interview. The donor reviews the questions on a computer
screen and enters the answers electronically. Your personnel review the answers.
Published studies have shown that computer-assisted interactive questionnaires that have
an audio component provide an effective method to elicit sensitive information from the
donors (Ref. 3, 4). [Note: Some blood collection facilities use computer programs to
display the questions to personnel, who question the donor and enter the responses into
2
Complete printed PDF page 4
Contains Nonbinding Recommendations
the computer. We do not address this process in this guidance because it is not a self-
administered process.]
The recommendation in our draft guidance entitled “Streamlining the Donor Interview Process:
Recommendations for Self-Administered Questionnaires,” dated April 2002, to not allow new
donors to self- administer the donor questionnaire was discussed at the Blood Products Advisory
Committee meeting on September 12, 2002. The committee pointed out that all the methods for
administering the donor questionnaires were comparable for eliciting information from new
donors, but stated that additional studies were needed to determine the efficacy of the various
methods to provide a safe blood product. Because the methods are comparable, we have
removed that recommendation from this final guidance. Consistent with the final guidance, new
donors may self-administer the donor questionnaire.
This guidance does not address the informed consent process. We also do not address specific
screening questions, a specific questionnaire, or, for licensed blood establishments, how to
submit changes to the questions on your currently approved questionnaire. Instead, this guidance
describes how you may change your current pre-donation donor screening interview procedure to
a self-administered format.
This guidance also advises licensed blood establishments how to report the change to a self-
administered questionnaire format to FDA under § 601.12, “Changes to an Approved
Application,” and what information they should submit. Licensed blood establishments that are
already approved to implement a self-administered donor questionnaire do not need to report this
change again to FDA. Unlicensed registered blood establishments implementing self-
administered donor questionnaire procedures do not need FDA approval for this change. Both
licensed and unlicensed registered blood establishments are subject to the Current Good
Manufacturing Practice (CGMP) regulations in 21 CFR Parts 210, 211, and 606, as well as all
other applicable regulations, including product standards in Part 640 and the computer record
keeping requirements of 21 CFR Part 11.
III. 	RECOMMENDATIONS FOR IMPLEMENTING SELF-ADMINISTERED
DONOR QUESTIONNAIRES
A. 	Recommendations for All Self-Administered Procedures
1. 	You must describe the self-administered procedures in your written
standard operating procedures (SOPs) (§ 606.100(b)). You must
adequately train your personnel in these procedures (§ 600.10(b) and
606.20(b)).
2. 	The donor must complete the self-administered questionnaire on the day
of donation (§§ 640.3(a) and 640.63(a)) before blood collection at the
donation site.
3
Complete printed PDF page 5
Contains Nonbinding Recommendations
3. 	You must provide an appropriate environment for individuals to complete
their donor questionnaire in a private setting (§ 606.40(a)(1)). You should
ensure that the donor is answering the questions in a confidential setting.
4. 	You should have a method at each donation to ensure that the donor
understands the questions (e.g., additional verbal or written questions).
This should include an evaluation of the donor’s ability to read and
understand the language of the self-administered questionnaire, regardless
of its medium (written, audio, or visual). Published studies have shown
that individuals with low medical literacy may not reliably complete self-
administered questionnaires (Ref. 5). You must defer donors who do not
appear to be providing reliable answers to the questions (§ 640.63(d)).
5. 	You should provide options for donors who prefer direct oral questioning
or who would like or need assistance in completing the questionnaire.
6. 	You should provide the donor with written or verbal instructions on how
to properly complete the questionnaire, including how to request
assistance, if needed. The instructions and questionnaire should be in a
language that the dono r readily understands. You should instruct the
donor to read and/or listen to the full question before answering and leave
the answer blank if he or she does not understand a question. Your
personnel should be available to answer questions.
7. 	The donor should answer all applicable questions on the questionnaire, as
defined by your SOP. The donor does not need to complete the
questionnaire if he or she is deferred early in the questioning process.
8. 	You should have a method to review the questionnaire for completeness
and accuracy before allowing the donor to donate and to question the
donor further, when necessary to determine the donor’s suitability. If you
modify answers or document the donor’s answer to blank questions after
clarification from the donor, you should annotate the entries (e.g.,
reviewer’s initials, further explanation of comments). If there are multiple
reasons to defer the donor, you must document all reasons for deferral on
the donor record (§ 606.160(b)(1)(ii)).
9. 	If you revise your que stionnaire to include new or modified questions, you
should highlight, or otherwise draw attention to, the new or modified
questions for one year so that all donors (new donors and donors who have
previously donated at your facility) will be aware of the change. You
should have a method to ensure consistent implementation of revised
questionnaires.
10. 	You should monitor the effectiveness of the self- administered
questionnaire in identifying unsuitable donors (e.g., by evaluating post
4
Complete printed PDF page 6
Contains Nonbinding Recommendations
donation information reports, infectious disease marker rates, specific
deferral trends, biological product deviation reports, post-transfusion
infectious disease reports).
B. 	Additional Recommendations for the Use of Audio/Visual Tools
Current audio/visual (AV) technology may encompass electronic media such as
audiocassette tapes and compact discs, videotape (e.g., VHS), digital videodisks, and
digitized recordings played on a computer. You may use these media to present the
medical/health history and/or high-risk behavior questions as well as AIDS/HIV
educational materials to the donors. The donors may play these recordings and document
their answers to the questions.
In addition to the recommendations in section III.A, you should consider the following
item when implementing the self-administered questionnaire using audio and visual
media:
1. 	Before implementation and periodically thereafter, you should verify and
document that the audio portion is understandable, in accordance with a
written SOP. You should have a written SOP for administering the
questionnaire when the audio/visual tools are not available.
2. 	The content of the audio recording should match the information displayed
in the video. When you revise your written materials or questionnaire,
you should also change the video and audio recording to match the written
materials. If you provide the donor with written AIDS/HIV educational
materials, they should correlate with the video and/or audio recording.
3. 	If more than one donor will be listening to the audio and/or watching the
audio/visual display at one time, your SOP should include provisions
regarding the appropriate number of donors for joint listening or viewing
to ensure privacy when answering the questions.
C. 	Additional Recommendations for Computer-Assisted Interactive Procedures
In the self-administered computer-assisted interactive interview procedure, the donor
reviews the questions on a computer screen and enters the answers electronically into the
software program managing the interview process. The computer software may or may
not make decisions on the suitability of the donors depending on the responses to the
questions. Under Section 510 of the Federal Food, Drug, and Cosmetic Act, your
computer system’s functionality may require 510(k) clearance (Ref. 6).
The computer system used in the computer-assisted interactive interview procedure
includes any hardware and software needed to perform the process. It may be a stand
alone system, used solely to conduct the donor interview, or it may interface with other
computer systems at the same or other locations. It may be a desktop or laptop computer
5
Complete printed PDF page 7
Contains Nonbinding Recommendations
or a handheld device. The software may have data storage capabilities or may send data
to a printer for hardcopy printout. In addition, the computer system may be accessible
from a remote location. The user interface may present both video and audio data to the
user via monitors, headphones, etc. Donors and collection personnel may input data or
responses via keyboard, microphone, or a pointing device such as a mouse, touch screen,
or stylus. The system may use pictures or drawings to illustrate the topic of the displayed
questions.
In addition to the recommendations in sections III.A and III.B, you should consider the
following items when implementing the self-administered computer-assisted interactive
questionnaire:
1. 	You should validate all aspects of your computer system for its intended
use. You should perform this validation consistent with the provisions
contained in FDA guidance documents (Refs. 7-8) and in § 820.100.
2. 	The computer system record keeping functions, including electronic
signatures and records, must comply with the requirements in Part 11
(Refs. 9-10).
3. 	You should have a written SOP for administering the questionnaire when
your computer system is not available.
IV. 	PROCEDURES FOR SUPPLEMENTING THE BIOLOGICS LICENSE
APPLICATION TO INCLUDE THE USE OF SELF-ADMINISTERED DONOR
QUESTIONNAIRES
A. 	General Submission Information
If you change your donor interview process to include self-administering the high-risk
behavior questions, as described in this guidance, using your currently approved
questionnaire, you should supplement your license application and report this change to
us as a Changes Being Effective in 30 Days (CBE30) supplement under § 601.12(c) (Ref.
11).
If you change your donor interview process to include self-administering only the
medical/health history questions from your currently approved donor questionnaire (e.g.,
you are not changing the process for administering the high-risk behavior questions), you
may report this change to us in your Annual Report under § 601.12(d).
Licensed blood establishments that are already approved to implement a self-
administered donor questionnaire do not need to report this change to FDA. However,
you may wish to review your procedures to ensure that they are consistent with this
guidance. If you revise your procedures to be consistent with this guidance, you may
report this to us in your Annual Report under § CFR 601.12(d).
6
Complete printed PDF page 8
Contains Nonbinding Recommendations
B. 	Submission Content for All Self-Administered Procedures
For assistance in preparing your supplement, see our “Guidance for Industry for the
Submission of Chemistry, Manufacturing and Controls and Establishment Description
Information for Human Blood and Blood Components Intended for Transfusion or for
Further Manufacture and for the Completion of the Form FDA 356h ‘Application to
Market a New Drug, Biologic or an Antibiotic Drug for Human Use’” (Ref. 12). You
should include the following items in your supplement:
1. 	FDA Form 356h, “Application to Market a New Drug, Biologic or an
Antibiotic Drug for Human Use.”
2. 	A cover letter describing your request and the contents of your
submission.
3. 	A written SOP incorporating the self-administered questionnaire process.
Include a copy of the instructions to prospective donors on how to
complete the donor questionnaire and your procedures for determining and
documenting each donor’s ability to provide reliable answers. The SOP
should also include alternate procedures for when you cannot use your
self-administered process.
C. 	Additional Submission Content for Computer-Assisted Interactive
Procedures
In addition to the submission content described in section IV.B, you should include the
following items when supplementing your biologics license application to include the use
of the self-administered, computer-assisted interactive questionnaire:
1. 	The name of the software manufacturer, program name, and version or
release number.
2. 	A description of the capabilities and functions of the computer system
used by the blood establishment.
3. 	The addresses of any blood collection facilities where you will install the
computer system and a description of the interface between facilities, if
applicable.
4. 	The computer system user on-site validation protocol. If applicable, the
validation should include any interfaces with other computer systems.
You should not submit the actual validation data. Your validation data
should be readily available for review at the time of FDA inspections.
7
Complete printed PDF page 9
Contains Nonbinding Recommendations
5. 	An SOP that accurately incorporates the computer system manufacturer's
instructions for use. The SOP should include alternate procedures for
when your computer system is not available.
6. 	A copy of the printed questionnaire.
7. 	A printout of all screens.
V. 	FOR MORE INFORMATION
If you have questions regarding the self-administered questionnaire or about computer system
requirements, call the Division of Blood Applications, Center for Biologics Evaluation and
Research, at 301-827-3543 or fax 301-827-3534.
8
Complete printed PDF page 10
(http://www.fda.gov/cber/memo.htm)
(http://www.fda.gov/cber/guidelines.htm)*
. (http://www.fda.gov/cber/guidelines.htm)
(http://www.access.gpo.gov/su_docs/aces/aces140.html)
. (http://www.fda.gov/cber/guidelines.htm)
99. (http://www.fda.gov/cber/guidelines.htm)
Contains Nonbinding Recommendations
REFERENCES
1. FDA memorandum, “Revised Recommendations for the Prevention of Human
Immunodeficiency Virus (HIV) Transmission
(http://www.fda.gov/cber/memo.htm)
by Blood and Blood Products,” April 23, 1992.
2. FDA memorandum, “Revised Guideline for the Collection of Platelets, Pheresis,” October 7,
1988.
3. Cooley PC, Rogers SM, Turner CF, et al. Using touch screen audio-CASI to obtain data on
sensitive topics. Computers in Human Behavior, 2001; 17:285-93.
4. Turner CF, Ku L, Rogers SM, et al. Adolescent sexual behavior, drug use, and violence:
Increased reporting with computer survey technology. Science 1998; 280:867-73.
5. Al-Tayyib AA, Rogers SM, Gibble, JN, et al. Effect of low medical literacy on health survey
measurements. American Journal of Public Health, 2002; 92(9); 1478-81.
6. FDA Correspondence, Letter to Blood Establishment Computer Software Manufacturers,
March 31, 1994.
7. FDA, “Draft Guideline for the Validation of Blood Establishment Computer Systems,”
September 28, 1993.
8. FDA, “Guidance for Industry: General Principles of Software Validation; Final Guidance for
Industry and FDA Staff, “ January 11, 2002
9. FDA Final Rule, “Electronic Records; Electronic Signatures,” March 20, 1997 (62 FR 13430
13467)
10. FDA, “Draft Guidance for Industry: 21 CFR Part 11; Electronic Records; Electronic
Signatures, Scope and Application,” February 20, 2003.
(http://www.fda.gov/cber/guidelines.htm)*
11. FDA, “Guidance for Industry: Changes to an Approved Application: Biological Products:
Human Blood and Blood Components Intended for Transfusion or for Further Manufacture,”
August 7, 2001
12. FDA, “Guidance for Industry for the Submission of Chemistry, Manufacturing and Controls
and Establishment Description Information for Human Blood and Blood Components Intended
for Transfusion or for Further Manufacture and for the Completion of the Form FDA 356h,
‘Application to Market a New Drug, Biologic or an Antibiotic Drug for Human Use,’” May 10,
19
* These draft guidance documents have been issued but are not for implementation. Once
finalized, they will represent the Agency’s current thinking on that topic.
9
Complete printed PDF page 11