us-fda-guidance-65b9c37a7c8fe18509dcc903e520ab0d•Guide for Establishing and Maintaining a Calibration Constancy Intercomparison System for Microwave Oven Compliance Survey Instruments (FDA 88-8264)] (PDF Only)
Guide for Establishing and Maintaining a Calibration Constancy Intercomparison System for Microwave Oven Compliance Survey Instruments (FDA 88-8264)] (PDF Only)
us-fda-guidance-65b9c37a7c8fe18509dcc903e520ab0dGuide for Establishing and Maintaining a Calibration Constancy Intercomparison System for Microwave Oven Compliance Survey Instruments (FDA 88-8264)] (PDF Only)Guidance
Administrative guidance, not enacted legislation. This captured publisher edition preserves the listed document and attachments; later developments are not independently consolidated.
Submit Comments
Submit comments on this guidance document electronically via docket ID: FDA-2013-S-0610 - Specific Electronic Submissions Intended For FDA's Dockets Management Staff (i.e., Citizen Petitions, Draft Proposed Guidance Documents, Variances, and other administrative record submissions)
If unable to submit comments online, please mail written comments to:
Dockets Management
Food and Drug Administration
5630 Fishers Lane, Rm 1061
Rockville, MD 20852
All comments should be identified with the title of the guidance.
HHS Publication FDA 88-8264 Guide for Establishing and Maintaining A Calibration Constancy Intercomparison System for Microwave Oven Compliance Survey Instruments Revised March 1988 U S . DEPARTMENT OF HEALTH AND HUMAN SERVICES Public Health Service Food and Drug Administration Center for Devices and Radiological Health Rockville, Maryland 20857
PREFACE Public Law 90-602, t h e Radiation Control for Health and Safety Act of 1968 (the Act), d i r e c t s t h e Department of Health and Human Services t o evaluate production testing and quality control programs carried out by t h e .industry t o assure adequacy of safegaurds against hazardous electronic product radiation and t o a s s u r e t h a t t h e products comply with performance standards. Under t h e Act, manufacturers of microwave ovens, a product listed under 2 1 CFR 1002.61, are required to certify t h a t their microwave ovens are in compliance with all of t h e applicable provisions of t h e Federal Performance Standard for Microwave Ovens, 21 CFR 1030.10. In order t o comply with microwave emission level provisions of t h e performance standard, manufacturers must use properly calibrated microwave leakage measurement instruments in their production and quality control testing programs. This document has been prepared in order t o assist t h e microwave oven .manufac- turers in establishing and maintaining a calibration constancy intercomparison system for compliance survey instruments and replaces guidance previously issued by t h e C e n t e r for Devices and Radiological Health (the Center). The guide also contains sample documentation forms for recording calibration data. Checks on t h e calibration constancy and use of microwave survey instruments a r e two vital parts of a n adequate quality control and testing program. Please read t h e guide carefully. If your instrumentation program does not include all t h e aspects covered in t h e guide, you should modify your program. Any changes t o your quality control program must be reported t o t h e C e n t e r using t h e instructions found in P a r t 8.0 of the Guide for Preparing Reports of Radiation Safety of Microwave Ovens, March 1985. Walter E. Gundaker Director Office of Compliance
FOREWORD In October 1982, the Food and Drug Administration established the Center for Devices and Radiological Health (CDRH) by merging the Bureau of Medical Devices and the Bureau of Radiological Health. The Center develops and implements national programs t o protect the public health in the fields of medical devices and radiological health. These programs are intended to assure the safety, effectiveness and proper labeling of medical devices, to control unnecessary human exposure t o potentially hazardous ionizing and nonionizing radiation, and to ensure the safe, efficacious use of such radiation. The Center publishes the results of its work in scientific journals and in its own technical reports. These reports provide a mechanism for disseminating 'results of CDRH and contractor projects. They are sold by the Government Printlng Office and/or the National Technical Information Service. Also, CDRH technical reports in radiological health are made available t o the World Health Organization (WHO) under a memorandum of agreement between WHO and the Department of Health and Human Services. Three WHO Collaborating Centers, established under the Bureau of Radiological Health, continue to function under CDRH: WHO Collaborating Center for Standardization of Protection Against Nonionizing Radiations; WHO Collaborating Center for Training and General Tasks in Radiation Medicine; and WHO Collaborating Center for Nuclear Medicine. We welcome your comments and requests for further information. / john C. Villforth irector for Devices and Radiological Health
CONTENTS Page .................................................... Foreword i P r e f a c e ...................................................... ii 1.0 Introduction ................................................ 1 2.0 Procedures ................................................. 2 ................................... 2.1 Preoperational Procedures 2 2.2 DailyChecks ............................................ 2 2.3 Thirty-Day Check: Initial Establishment of t h e Reference FieId ....; ... 4 2.4 Thirty-Day Check: Initial Polarization Response Check .............................. of t h e Compliance Instruments 6 2.5 Thirty-Day Check: Constancy of the Reference Field and Compliance Instruments ................................ 2.6 Annual Calibration ........................................ 2.7 Periodic Recalibrations ...................................... 2.8 Repair ................................................. Appendixes 1. Calibration Constancy Intercomparison System .................... 11 2 . Block Diagram of t h e System ................................. 13 3. Daily Check Record ....................................... 14 4 . Renewal of Records ....................................... 15 5. 12-Month Historical Record .................................. 16 6 . Nonref erence Field Constancy ................................ 17 ............................ 7 . 30-Day Instrument Comparison Log 18 8. 2 dB Comparison Check Record ................................ 19 9. Flowchart for 30-Day Calibration Constancy Program ............... 2? .....
GUIDE FOR ESTABLISHING AND MAINTAINING A CALIBRATION CONSTANCY INTERCOMPARISON SYSTEM FOR MICROWAVE OVEN COMPLIANCE SURVEY INSTRUMENTS 1.0 INTRODUCTION Manufacturers of microwave ovens must use properly calibrated microwave leakage measurement instruments in their production testing and quality control programs to assure compliance with the Federal Performance Standard for Microwave Ovens (21 CFR 1030.10). As an alternative to frequent recalibration against absolute standards, the Center for Devices and Radiological Health (CDRH)will allow manufacturers to establish a system that demonstrates that the calibration of each instrument remains within prescribed limits, over time, subsequent to absolute calibration* by the instrument manufacturer or other qualified calibration facility. - This document outlines procedures for establishing and maintaining a "calibration constancy intercomparison system'' (referred to as the "system" throughout this document) capable of assuring adequate constancy of calibration, while minimizing the necessity for absolute recalibration. It must be noted and understood that the system described herein is not intended for use in calibrating hand-held or automated scanning survey instruments, nor is it intended to be used to transfer calibrations from one instrument to another. I t is only intended to provide a means to determine whether an instrument's calibration is changing with time, and whether it is continuing to function properly. The underlying principle is that constancy of calibration may be determined by comparing an instrument's reading with its own prior readings and with other meters' readings when it measures a fixed parameter. The procedures for establishing and maintaining a calibration constancy intercom- parison system consist of (1) maintaining an apparatus or system to perform a calibration constancy intercomparison, (2) documenting the results using a log or record to demonstrate constancy over a period of time, and (3) adhering to an appropriate schedule of checks to assure proper function and calibration constancy of each instru- ment. Such a schedule of checks and a simple acceptable calibration constancy inter- comparison system are described below. Briefly, the calibration constancy intercom- parison system consists mainly of: (1) a microwave source, (2) a radiated power monitor (RPM), (3) an anechoic environment with a radiator and probe-holding fixture, and (4) a local calibration reference (LCR). A more detailed description is given in Appendixes 1 and 2. A system using this apparatus has been demonstrated to be accurate and practical to reproduce and use. Any calibration constancy intercomparison system that can be shown to provide comparable performance (at least within the same limits as the system described above) would be acceptable. *Absolute calibration (i.e., cafibration against absolute standards) means calibration of a system in which all measurement parameters are traceable, with specified uncertainty, to the absolute standards maintained by the National Bureau of Standards or equivalent. 1
2.0 PROCEDURES 2.1 PREOPERATIONAL PROCEDURES 2.1.1 Requirement Preoperational procedures, as described by t h e manufacturers of t h e calibration constancy intercomparison system and t h e survey instruments, must be performed prior t o use t o assure t h a t t h e system and survey instruments are functioning correctly and properly adjusted. 2.1.2 Instrumentation and Method Various preoperational procedures a r e described in t h e manuals provided by t h e manufacturers of t h e calibration constancy intercomparison system and survey instru- ments. For example: -- (1) a suitable period of time must be allowed a f t e r turning on t h e system and survey instruments for nwarm up1' o r stabilization; (2) survey instruments' probe cones (spacers) should be checked daily and replaced if dirty o r worn; (3) battery-operated survey instruments must have their batteries checked thoughout the day; (4) charger covers must be in place. on t h e survey instruments with rechargeable batteries; (5) the voltage supply for t h e AC-voltage powered instruments must be checked periodically; (6) the survey instruments and system should be checked f o r any evidence of physical damage, and, if damaged, t h e entire instrument and/or system must .be checked prior t o e a c h oven survey; (7) baseline o r "zero1' reading on t h e survey instruments and/or system must be checked prior t o each oven survey; and (8) all o t h e r preoperational procedures specified in t h e owner's survey instrument and/or system manuals must be followed. 2.2 DAILY CHECKS 2.2.1 Requirement The polarization response of e a c h survey instrument must be checked daily prior t.0 i t s use t o determine any gross shifts in response which could indicate instrumen'f damage. *..
2.2.2 Instrumentation and Method Make a check of the survey instrument's polarization response using an adequately stable microwave field source. This microwave field should be linearly polarized, have the correct frequency, and cause at least a mid-scale meter reading on the survey instrument. A field setting (or power density) of approximately 1.0 mW/cm2 can be used for generating a mid-scale meter reading. However, different levels may be necessary for other specialized meters such as probe/pre-amp units from the automated oven survey systems (scanners). Specifications for performing polarization response measure- ments should be obtained from the survey instrument manufacturer. A probe-holding fixture must be provided to keep the probe on a constant axis while the probe is slowly rotated (approximately 2 revolutions per minute) about the axis normal to its detection plane (usually the handle axis). Because unnecessary changes in the probe orientation or position may alter the measurement of polarization ellipticity, the probe fixture should prevent any unnecessary horizontal, vertical, or transverse motion while the probe is being rotated (see Figure 1). - Figure 1. Probe rotation should prevent any horizontal, vertical, or transverse motion while the probe is being rotated . Because each survey instrument has its own ellipse of polarization response (also known as polarization ellipticity error), the percentage or polarization error of each instrument must be calculated to determine whether each instrument is operating within the limit of the manufacturer's specification. A common way to find the percentage of polarization ellipticity error is as follows: (1) place the probe in the fixture and turn on the microwave power source so the survey meter reads a mid-scale value (for example 1.0 m W/cm2); (2) rotate the probe 360 degrees and note the minimum and maximum readings and calculate the mean (see Equation 1); and (3) calculate the percentage of polarization ellipticity error using Equation 2. The result must be equal to or less than the percentage error limit of polarization ellipticity specified by the instrument manufacturer (e.g., +5 percent, or a total of 10 percent). Any instrument with a polarization ellipticity error greater than the allowed tolerance must be repaired or discarded. Ano:her way to find the percentage polarization ellipticity error is as follows: (1) place the probe in the fixture and turn the power on so the survey meter .reads a' mid-scale value of 1.0 mW/cm2; (2) rotate the probe 360 degrees and find the minimum reading only;
(3) change t h e power s e t t i n g until t h e survey meter reads 1.0 mW/cm2 at t h e mini- mum polarization response; (4) r o t a t e t h e probe again t o obtain t h e highest polarization response reading; and (5) s u b t r a c t 1.0 from t h e highest polarization response reading and multiply t h e result by 100. The result must b e equal t o o r less than t h e t o t a l percentage polarization ellipticity error specified by t h e instrument manufacturer (see Equation 3 below). Maximum + Minimum Mean = Maximum - Minimum % Total Polarization Ellipticity Error = Mean Note: to get _+ percent, divide Total by 2 %Total Polariuztion Error = (Maximum - 1.011 00 (3) ' For example, a total error for this procedure of 10 percent is equivalent t o t h e survey instrument manufacturer's specification of f5 percent polarization ellipticity error. The daily check method applies t o instruments employing planar detectors. Alternate methods for other types of detectors may need t o be developed. 2.2.3 Documentation A s e p a r a t e "daily check" record should be kept for every survey instrument for com- pliance testing on t h e production line and audit. The record should include: t h e model and serial number of t h e instrument (probe modevserial number if necessary), t h e percentage e r r o r in polarization ellipticity specified by t h e instrument manufacturer, t h e results of t h e test, and t h e name of t h e person who performed t h e test. If an instru- ment fails t h e test, t h e disposition of t h e instrument should be clearly indicated in t h e "re marks" column. Following t h e repair, t h e instrument's record must be renewed (e.g., s t a r t e d over). See Appendix 3 f o r a n example of t h e documentation; any equivalent c h a r t is acceptable. Appendix 4 of this guide contains a c h a r t which describes briefly when and under what circumstances certain records must be renewed. 2.3 THIRTY-DAY CHECK: INITIAL ESTABLISHMENT OF THE REFERENCE FIELD 2.3.1 Requirement A reference field must be established prior t o checking t h e 30-day calibration con- s t a n c y of every instrument (including spare scanner probes o r hand-held survey meters) used for microwave oven compliance determinations. 2.3.2 Instrumentation and Method of Establishing t h e Reference Field Using t h e LCR One instrument suitable for compliance determinations is set aside and not used for production o r quality control t,esting. I t is retained as t h e local calibration reference (LCR),having been calibrated by i t s manufacturer o r other suitable source. This instru- ment is s e t aside t o minimize t h e probability of damage and/or loss of calibration
through accident o r t h e wear and t e a r of normal use. It is recommended t h a t t h e instru- ment selected as t h e LCR have a power density calibration which is near t h e geometric mean of t h e power density calibrations of a l l instruments used f o r compliance determination (e.g., if t h e spread of calibration factors is .98 t o 1.08, then t h e LCR should have a f a c t o r near 1.03). It is also recommended that t h e LCR be of t h e s a m e b r a n d m a k e as t h e survey instruments being checked. An LCR is not t o be misconstrued as a transfer standard. If i t s calibration is 41 dB, it cannot be used a s a transfer standard for instruments whose accuracy is also f l dB. Using t h e calibration constancy intercomparison system, an initial reference field is established with t h e probe of t h e LCR positioned a t t h e mean of i t s polarization ellipse. Set t h e field at a power density of approximately 1.0 mW/cm"s read on t h e LCR. The mean of t h e polarization ellipse of t h e LCR must be located by finding t h e mean of t h e maximum and minimum readings when the LCR probe is slowly rotated 360 degrees in the calibration constancy intercomparison system chamber. When the LCR probe is positioned in t h e system at t h e mean of its polarization ellipse, t h e power density can be adjusted (if necessary) t o t h e appropriate reference field (usually 1.0 m W/cm2). The values of t h e reference field should be specified by t h e instrument manufacturer o r calibration facility. A f t e r s e t t i n g t h e reference field, t h e percentage of polarization error of t h e LCR must be checked t o verify t h a t i t meets t h e instrument manufacturer's specification. When t h e reference field has been s e t up using t h e LCR, i t is important that the readings on t h e radiation power monitor (RPM), (e.g., Forward, Reflected, and Difference (Net)) o r from another power meter a r e recorded and noted on t h e log record (Appendix 5). 2.3.3 Instrumentation and Method of Establishing t h e Reference Field Using t h e RPM (Optional) An a l t e r n a t i v e method for establishing t h e reference field can be performed by using t h e radiated power monitor (RPM). After t h e LCR has been calibrated by i t s manu- f a c t u r e r o r o t h e r suitable source, use t h e LCR t o find t h e mid-scale value (e.g., obtain a 1.0 mW/cm2 midpoint scale reading on t h e LCR, then record t h e RPM readings). For t h e subsequent monthly checks, t h e reference field can be s e t by using the RPM t o repeat the same reading obtained t h e first month. When the reference field has been set up using the RPM, i t is important t h a t t h e readings from t h e LCR a r e recorded and noted on the log record (Appendix 5). 2.3.4 Documentation A "12-month historical record" should be kept on t h e reference field instruments. Both the LCR readings (Minimum, Maximum, and Mean readings) and RPM net power readings (Forward, Reflected, and Difference) a r e t o be recorded and noted as reference readings. O t h e r items such a s ambient temperature and t h e name of t h e person who performed t h e t e s t s should also be recorded. If t h e LCR fails t h e polarization ellipticity check, the disposition of t h e LCR should be clearly indicated in t h e "remarks" column. Following t h e repair of t h e LCR, t h e 12-month historical record and all o t h e r records must be renewed (see Appendix 4). See Appendixes 5 and 6 f o r example:: of t h e docu- mentation; any equivalent c h a r t s a r e acceptable.
2.4 THIRTY-DAY CHECK: INITIAL POLARIZATION RESPONSE CHECK O F THE COMPLIANCE INSTRUMENTS 2.4.1 Requirement A f t e r t h e reference field has been established at a specified power density (for example 1.0 mW/cm" as described in P a r t 2.3.2 o r 2.3.3, t h e polarization response of each survey instrument t o be used for compliance testing must be initially checked. T h e polarization ellipticity error of each survey compliance instrument must meet t h e instrument manufacturer's specification. This initial check must be performed prior t o initial use on t h e production line, when i t is taken out of spare stock, o r a f t e r i t has been returned from repair. 2.4.2 Instrumentation and Method Follow t h e s a m e procedures outlined in P a r t 2.2.2 above. - - 2.4.3 Documentation For each instrument used in ~ r o d u c t i o no r in audit, a separate "30-day instrument comparison log" record should de maintained. This log should include t h e following. model and serial number of each instrument (and probe model and serial number if necessary); date; t h e minimum, maximum, and mean of t h e polarization response readings; percentage of polarization ellipticity error; t h e highest and lowest mean readings since t h e last calibrationhepair; and verification t h a t each instrument met t h e polarization ellipticity e r r o r limit specified by t h e instrument manufacturer. If t h e instrument's polarization ellipticity error is outside t h e specification, t h e disposition of t h e instrument should be clearly indicated on t h e record. See Appendix 7 for an exam- ple of t h e documentation; any equivalent chart is acceptable. 2.5 THIRTY-DAY CHECK: CONSTANCY O F REFERENCE FIELD AND COMPLIANCE INSTRUMENTS 2.5.1 Requirement f o r t h e Reference Field The reference field must be established for t h e initial setup of t h e system and survey instruments (see P a r t 2.3). For t h e subsequent monthly checks, the power density of t h e reference field in t h e calibration constancy intercomparison system should be re- established by adjusting t h e microwave power source t o repeat either t h e previous LCR or R P M reference reading. A f t e r t h e reference field is reset using one of these two readings, t h e o t h e r reading (from t h e RPM o r LCR) must agree with all of i t s preceeding readings within 10 percent. That is, no two of these nonreference readings, from one annual calibration o r repair t o t h e next, may disagree by more than 10 percent. For example, if t h e r e f e r e n c e field is set using t h e reading of t h e LCR, then t h e monthly RPM (Diff) nonreference readings (ail readings accumulated since t h e last LCR calibration) must be verified t o be within 10 percent of e a c h other. If t h e reference field is s e t using readings of t h e RPM, t h e n t h e monthly LCR nonreference mean readings (all mean readings accumulated since t h e last LCR calibration) of t h e polari: zation ellipse must be verified t o b e within 10 p e r c e n t of e a c h other. If t h e ' nonreference readings disagreed by more than 10 percent, then t h e nonreference instru- ment must be repaired (or discarded). See Appendix 6 f o r a n example of t h e documen- t a t ion. Following these act ions, new 12-month historical records (Appendixes 5 and 6), and all other records, must be renewed (see Appendix 4).
2-5.5 Requirement f o r Each Compliance Instrument A f t e r e a c h compliance survey instrument receives i t s initial check of t h e polari- zation ellipse (see P a r t 2.4.1), t h e mean reading of each instrument must then be compared with all of i t s own previous monthly mean readings f o r constancy within 10 percent. For t h e comparison, use only those mean readings taken since t h e survey instrument was last calibrated (or repaired), o r from when t h e LCR (or RPM) was last calibrated, whichever is most current. For those survey instruments falling outside t h e 10 percent limit, possible sources of t h e failure must b e traced. First, t h e survey instrument itself should be checked for obvious problems such as weak batteries. Second, t h e system should be examined. Problems with equipment must be adequately resolved before proceeding further. If t h e problem was t r a c e d t o t h e survey instrument, then the survey instrument must be repaired (or discarded) and t h e 30-day instrument comparison log (Appendix 7) and daily check record (Appendix 3) for t h a t compliance survey instruments must be renewed. If the problem was t r a c e d t o t h e system, then t h e system must be repaiped and all records must be renewed. See Appendix 4 f o r further explanation regarding reiiewal of records. 2.5.3 Requirement for Calibration D a t a Constancy The least sensitive and most sensitive survey instruments (including the LCR) must not disagree by more than 2 dB, including t h e extremes of polarization ellipse. A monthly.2 dB check must be performed by comparing t h e ratio of t h e highest polariza- tion ellipse reading from all of t h e instruments (including t h e LCR) t o t h e lowest polarization ellipse reading from all of the instruments (including t h e LCR). This ratio must not exceed 1.59 (2 dB). Do not include those instruments t h a t did not pass t h e daily check or t h e 1 0 percent comparison' in t h e 30-day check. The 2-dB check of instruments e a c h month is done on a cumulative baiis; t h a t is, t h e comparison period is t h e time between LCR calibrations (or repairs). If, during t h e comparison check, t h e ratio exceeded 1.59 (or 2 dB), then t h e e n t i r e system, including t h e L C R and individual compliance survey instruments, must be examined and repaired as necessary. Repeat t h e 10 percent comparison check of t h e individual survey instruments (see P a r t 2.5.2). Problems with all of the equipment must be adequately resolved before proceeding further. Then repeat t h e 2 dB comparison check t o d e t e r m i n e that t h e ratio is less than o r equal t o 1.59 and ensure that any remaining d e f e c t i v e instruments a r e found. Following these actions, then a new 2 dB comparison c h e c k record (Appendix 8) and most o r all other records must be renewed (see Appendix 4). Appendix 9 illustrates the proper 30-day constancy check sequence in t h e form of a flowchart. 2.5.4 Documentation Two s e p a r a t e records must be maintained. T h e first record, "30-Day Instrument Comparison Log" (Appendix 7), should be kept f o r every instrument used on t h e produc- tion line and in audit. T h e 30-day instrument comparison log should verify t h a t t h e highest and lowest mean readings of t h e individual instrument are within 10 percent of e a c h other. If not, t h e disposition of t h e instrument should b e clearly indicated on t h e records. Following these actions, t w o new records, one f o r recording results of t h e daily) check (Appendix 3) and a second, t h e 30-day instrument comparison log (Appendix 7), must be s t a r t e d (see Appendix 4).
The second separate record, "2 dB Comparison Checktt (Appendix 8), should be kept t o monitor t h e calibration d a t a constancy of all t h e instruments used on t h e production line and in audit since t h e last LCR calibration. Exclude those instruments t h a t did not pass the daily check, and/or t h e 10 percent comparison in t h e 30-day check. This record should include t h e highest and lowest polarization response readings taken from all of t h e instruments (including t h e LCR). These values should be compared and t h e ratio of t h e highest polarization ellipse reading t o t h e lowest polarization ellipse reading during t h e entire period should be less than 1.59 (2 dB). If t h e r a t i o exceeds 1.59, make a complete check of t h e entire system and record t h e reason f o r failure. If t h e failure is traced t o a defective individual survey instrument, t h e survey instrument must be taken out of production o r audit facility for repair. Then continue t o use t h e same 2 dB comparison check log. When t h e repaired survey instru- ment comes back, renew t h e 30-day instrument comparison log (Appendix 7) and daily check record (Appendix 3) for t h e survey instrument. If t h e problem is traced t o t h e system, then a new 2 dB comparison check record and all other records must be s t a r t e d following correction of t h e problems (see Appendix 4). See Appendix 8 for a n example of t h e documentation; any equivalent chart is acceptable. 2.6 ANNUAL CALIBRATION 2.6.1 Requirement Absolute calibration of t h e LCR must be performed annually. There'may be a need for annual absolute calibration of compliance survey instruments, scanner probe/pre- amp, radiated power monitor (RPM), power meter, etc., depending upon t h e recommen- dations of t h e instrument manufacturer. It is important that t h e microwave oven manufacturer check with t h e instrumenta- tion manufacturer for specifications o r recommendations concerning annual calibration. Whenever t h e LCR has returned a f t e r being calibrated and/or repaired, it is important t o immediately determine its percentage of polarization ellipticity error and record t h e results (see P a r t 2.3). 2.6.2 Instrumentation and Method The LCR must be returned t o t h e instrument manufacturer or other qualified cali- bration facility for absolute calibration (12-month intervals). Some compliance survey instruments o r o t h e r electronic components of t h e system also may require absolute calibration annually. 2.6.3 Documentation A separate record of t h e LCR calibration and repair should be kept. This log should include model and serial number, calibration date, and a list of any repairs and their dates. The 12-month historical record (Appendix 5) of t h e LCR is renewed every t i m e t h e LCR h r s been returned from annual calibration. The 30-day instrument comparison log of each compliance survey instrument (as well as scanner probe/pre-amp units) is renewed when t h e LCR has been returned from annual calibration.
2.7 PERIODIC RECALIBRATIONS 2.7.1 Requirement The absolute .calibration of all instruments should be performed periodically. 2.7.2 Instrumentation and Method In accordance with good engineering and manufacturing practice, i t is recommended t h a t all instruments used t o make compliance determination measurements (with t h e exception of LCR and RPM) be returned t o t h e instrument manufacturer factory o r o t h e r qualified calibration facility f o r absolute calibration at least once every 3 years. 2.7.3 Documentation See P a r t s 2.2.3 and 2.3.4 -- 2.8 REPAIR 2.8.1 Requirement Any instrument which has been found t o . b e damaged o r failed t o remain within its established constancy limits must not be used in t h e quality control and testing program until it has been repaired and recalibrated by a n instrument manufacturer o r other qualified calibration and repair facility. Before repaired instruments a r e used again, t h e i r operational functions and their polarization respons6s must be checked (see P a r t 2.2). Following these actions, t h e instrument's records must be renewed (see Appendix 4). It is recommended t h a t repairs be performed only by t h e instrument manufacturer o r o t h e r qualified calibration facility unless t h e microwave oven manufacturer has in place an adequate repair facility t o perform certain minor repairs (such as broken probe cables, d e f e c t i v e meters, etc.) and has t h e capability of checking t h e i r results. Microwave oven manufacturers will be required t o submit specific technical repair procedures t o CDRH for review before implementing them. 2.8.2 Instrumentation and Method Whenever t h e compliance survey meters, LCR, o r scanner probe/pre-amp units a r e returned from t h e instrument manufacturer a f t e r repair, t h e i r polarization ellipse must . be checked against t h e instrument manufacturersf specifications and verified on t h e record prior t o their use. 2.8.3 Documentation The disposition of t h e defective instrument can be recorded in t h e "remarks" column.
APPENDIX 1 CALIBRATION CONSTANCY INTERCOMPARISON SYSTEM A block diagram of the calibration constancy intercomparison system is provided in Appendix 2. The parenthetical numbers preceding each paragraph below and used within those paragraphs refer t o the numbers in the Appendix 2 diagram. (1) SOURCE The source is a microwave generator with (a) an appropriate power output (probably approximately 0.5 to 5 0 Watts maximum output) that may be variable (either internally or by some external attenuator) and (b) a frequency in the relevant ISM band (915 5 25 MHz or 2 4 5 0 + 50 MHz). Depending on the radiator or anechoic enclosure and on the inherent frequency stability of the source, some control over the source output fre- quency may be necessary. The source might be a magnetron or klystron oscillator, or might be a low-powered source amplified, e.g., by a traveling wave tube amplifier. However, any type of source with adequately stable or controllable output parameters could be used. (2), (3), (4) DIRECTIONAL COUPLERS The directional couplers are used to sample a fixed fraction of the power flowing through them in either the forward 'or reverse direction. This fraction should be chosen so as to deliver a signal to items (5), (6), or (7) which is of a magnitude appropriate t o the specific device. Furthermore, this fraction (or ffcoupling factor") must be adequately invariant with frequency over the range of- frequency variations of the source. Two of these couplers might be replaced by a single bi-directional coupler if desired. Furthermore, if the source has some built-in frequency monitor, (4) might be eliminated. Couplers (2) and (3) should be adequately insensitive to power flowing in a direction opposite to that intended t o be measured (i.e., these couplers should have adequate "directivityf'). I t is not absolutely necessary that directional couplers be used, however some means of differentiating between forward and reflected power (to allow determination of net radiated power) must be included. (S), (6) POWER METERS These power meters must provide repeatable, adequately sensitive, and reliable re- sponses to both absolute levels and relative variation of power. They should be rela- tively insensitive t o frequency variation. I t may be necessary to insert attenuators between the directional couplers and the power meters to bring the input to the power meters into an appropriate range. I t is not absolutely necessary that power meters be used for these applications. Whatever type of detector is used, some reliable means of calibration must be employed in an annual calibration. In the system illustrated, if the source can be demonstrated to be adequately stable, a single pqwer meter might be alternatively switched to the output of the couplers (2) and (3) by means of a coaxial switch. The power meter or meters and directional couplers form the radiated power monitor (RPM). (7) FREQUENCY MEASURING DEVICE Some means must be employed to verify that the frequency of the radiated signal remains within appropriate limits. These limits are closely related t o the quality of the
anechoic environment (9). If standing waves of considerable magnitude exist within this environment, a change in t h e frequency of t h e radiated signal can cause a variation in t h e spatial distribution of t h e field and have a significant e f f e c t on t h e reading of a stationary probe in t h e fixture (10). Thus, t h e choice of both source (1) and anechoic environment (9) must be made with this phenomenon in mind. Although frequency counters are o f t e n available in microwave laboratories, any of several other possibilities might be employed (e.g., a tunable cavity might be used with a crystal o r power m e t e r monitoring t h e output). Clearly, t h e use of a n anechoic environment of appropriate characteristics with an adequately s t a b l e source can eliminate t h e necessity t o employ t h e frequency measuring device shown in t h e illustration. (8) RADIATOR Some means of radiating t h e generated power into space must be provided. :Among a multitude of possible devices t h a t might be 'employed for this purpose a r e horn, log periodic and dipole antennas, a s well a s flared o r simply open-ended waveguide sections. Considerations in t h e choice include directivity of t h e radiator vs. the reflectivity and absorption of t h e anechoic environment, as well as the frequency response of t h e radi- a t o r vs. t h e source frequency stability. If a stable source is t o be employed, a wave- guide or coaxial tuner may be employed t o improve t h e system match t o the radiator t o minimize reflected power. (9) ANECHOIC ENCLOSURE An anechoic environment should be provided t o minimize t h e effects of t h e labora- tory environment on t h e measurement. The quality and size of this anechoic environ- ment will determine t h e magnitude of t h e standing wave in t h e region of t h e instrument under comparison. (10) PROBE-HOLDING FIXTURE A stable fixture t o hold the instrument being evaluated in a rigid, repeatable position must be employed. This fixture should be made of an electrically non-conductive material t o minimize standing waves and perturbations of t h e fields. In general, t h e g r e a t e r t h e magnitude of t h e standing wave and t h e closer t h e probe t o the radiator, t h e more critical a r e t h e repositioning requirements of this fixture.
APPENDIX 4 IZENDWAL OF RECORDS Documentation Forms Appcndix 3 Appendix 5 Appendix 6 Appendix 7 Appendix 8 Daily Check 12-Month Nonreference 30-Day Instrument 2 dB Comparison Status Record Historical Record Constancy Comparison Log Check Daily Check (2.2) Failed survey instruments , Renew Same Same Same Same LCRIRPM Monthly (2.3.2 - 2.3.3) Polarization failure of LCR Renew Renew Renew Failed RPM Renew Renew Renew 30-Day Check of Individual Survey Meters (2.4.1,2.5.2) Polarization failure Renew Same P 10% comparison failure Renew Same VL 30-Day Check of Nonreference Meter (2.6.1) 10% comparison failure Renew Renew 2 dB Comparison (2.5.3) System or LCR failure Survey meter failure Renew Renew Renew Same Renew Renew Renew Renew Same Renew Same Same Renew Same Renew Renew Same Renew Renew Renew Renew Renew Same LCR Calibration (2.6) Annual calibration Renew Renew Renew , , Renew Renew Numbers in parentheses refer to sections of this report.
APPENDIX 5 12-MONTH HISTORICAL RECORD Name of constancy system: Date of last LCRIRPM calibration: Make of LCWRPM: Model number of LCWRPM: Serial number of LCR: Probe model number on LCR: Probe serial number on LCR: LCR Polarization Ellipticity Readings RPM RPM RPM LCR LCR LCR LCR Ambient Date , Fwd Rev Diff Max Min Mean % Ellip Temp Remarks NOTES: (1) The LCR must be positioned a t its mean polarization response prior to setting the reference field. ' (2) If the reference field is set using the LCR readings, then the monthly RPM (Diffl readings must be within 10%. ,(3) If the reference field is set using the RPM readings, then the monthly LCR (Mean) readings must be within 10% (4) If the readings taken from the nonreference instrument disagreed by more than lo%, then this instrument must be repaired (or discarded). Following these actions, a new Daily Check Record (Appendix 3) and all other records, must be renewed (2.5.1). Maximum + Minimum Mean = 2 ~ a i i r n u m- Minimum % Tota 1 Pola rizatwn Ellipticity Error = Mean % Total ellipticity error limit specified by LCR instrument manufacturer is:
APPENDIX 6 NONREPERENCE FIELD CONSTANCY The monthly reference field is set by (check one only): LCR RPM If you selected the LCR to set the monthly reference field, use column 1 only. If you selected the R P M to set the monthly reference field, use column 2 only. Column 1 Column 2 Monthly (A) Highest (B) Lowest (A) Highest (B) Lowest Less than 1.lo? Date RPM Diff (or P) RPM Diff (or P) LCR Mean LCR Mean A/B (YesINol* * NOTES: If the reference field is set using the reading of the LCR, then the monthly RPM (Dim nonreference readings (all readings accumulated since the last LCR calibration) must be verified to be within 10 percept. of each other. If the reference field is set *: using readings of the RPM, then the monthly LCR mean nonreference readings (all mean readings accumulated since last LCR calibration) of the polarization ellipse must be verified to be within 10 percent of each other. If the nonreference readings failed the 10 percent comparison test, then the nonreference instrument must be repaired and recalibrated. Following this action, all records must be renewed.
.paMauaJ aq ? s n w pJoaaJ s!q? uaqJ '(pap.ms!p J O ) pa?e.lq!leaa.r put? pa.I!odaJ aq I s n u ?! ' a ~ g ~ a j a p s! Ja?aur X a ~ ~ n s aq?jI (E) ' ~ a ~ n ? 3 8 j n u ~ u r ?uaurnJ?su! aq? ;Cq pag!mds ?!ur![ J o u a X?!x?d!lla uo!?t?z!~elodlelo?% aq? waur ? s n w luaurn.wu! q x r 3 (z) . u o ! ? e ~ q g e 3a37 p n u u w uaam?aq lt?,walu! ay? Bu!.Inp (IsaMolo? ?saq8!q) a8ue.1 %OI u ! q ? ! ~aJr, s8u!pt?a~u v a w ay? ~ e y ~ L p a ~( I ) :S~J,ON
APPENDIX 9 FLOWCHART FOR 30-DAY CALIBRATION CONSTANCY PROGRAM . . Start new records I Check polarization ellipse o f LCR 1 LCR probe positioned t o read - + -- - Set field inside system (usually 1 m~lcrn'). Record LCR and RPM settings. I Polarization OK? > No Correct or repair & recalibrate C or RPM reference RPM I , All previous RPM DlFF t I yes readingswithin lo%? I Calculate % ellipticity error. I I Yes Set field (usually 1 m ~ l c m ~ ) . Check polarization of each Yes compliance meter. Record MAX, MIN. & MEAN. No , < Has LCR been calibrated i n last 12 months? of o w n highest reading since I last LCWRPM calibration? \ Yes C rument mean reading within 10% No - Repa~ror replace instruments Yes If problem found All instrument readings, including No within system or LCR. within 2 dB since last LCR ) reference instru- calibration? ment, have it repaired or replaced Yes L j individual 1 .