Certain Human Cells, Tissues, and Cellular and Tissue-Based Products (HCT/Ps) Recovered from Donors Who Were Tested for Communicable Diseases Using Pooled Specimens or Diagnostic Tests: Guidance for Industry

us-fda-guidance-60f569f22809c1e3c368ae406f5c6351Certain Human Cells, Tissues, and Cellular and Tissue-Based Products (HCT/Ps) Recovered from Donors Who Were Tested for Communicable Diseases Using Pooled Specimens or Diagnostic Tests: Guidance for IndustryGuidance

Administrative guidance, not enacted legislation. This captured publisher edition preserves the listed document and attachments; later developments are not independently consolidated.

Docket Number:
FDA-2007-D-0070
Issued by:
Guidance Issuing Office
Center for Biologics Evaluation and Research

This guidance provides you, an establishment1 that makes donor eligibility determinations for certain human cells, tissues, and cellular and tissue-based products (HCT/Ps), with recommendations concerning the donor eligibility and additional requirements under Title 21 Code of Federal Regulations, Part 1271, Subpart C (21 CFR Part 1271, Subpart C). This guidance updates and replaces the January 2007 guidance of the same title to clarify that for the purposes of this guidance the term “certain HCT/Ps” also includes certain donor lymphocytes for infusion (DLIs), namely those lymphocytes for infusion collected from the same donor as hematopoietic progenitor/stem cells (HPCs); • provide updated recommendations regarding donor testing2 using pooled specimens of HPCs and DLIs (as specified above) due to the approval of Biologics License Application (BLA) supplements from two nucleic acid test manufacturers (see footnotes 5 through 7); and • specify that this guidance applies to certain HCT/Ps recovered from donors beginning on or after May 25, 2005 through February 23, 2007.


Submit Comments

You can submit online or written comments on any guidance at any time (see 21 CFR 10.115(g)(5))

If unable to submit comments online, please mail written comments to:

Dockets Management
Food and Drug Administration
5630 Fishers Lane, Rm 1061
Rockville, MD 20852

All written comments should be identified with this document's docket number: FDA-2007-D-0070.

Questions?

Contact Point
Office of Communication, Outreach and Development (OCOD)
Center for Biologics Evaluation and Research
Food and Drug Administration
10903 New Hampshire Ave WO71-3128
Silver Spring, MD 20993-0002
ocod@fda.hhs.gov
(800) 835-4709
(240) 402-8010
Guidance for Industry
Certain Human Cells, Tissues, and
Cellular and Tissue-Based Products
(HCT/Ps) Recovered From Donors
Who Were Tested For Communicable
Diseases Using Pooled Specimens or
Diagnostic Tests
This guidance is for immediate implementation.
FDA is issuing this guidance for immediate implementation in accordance with 21 CFR
10.115(g)(4)(i). Submit written comments on this guidance at anytime to the Division of
Dockets Management (HFA-305), Food and Drug Administration, 5630 Fishers Lane, Rm. 1061,
Rockville, MD 20852. Submit electronic comments to http://www.regulations.gov. You should
identify all comments with the Docket Number 2007D-0017.
Additional copies of this guidance are available from the Office of Communication, Training and
Manufacturers Assistance (HFM-40), 1401 Rockville Pike, Suite 200N, Rockville, MD 20852-
1448, or by calling 1-800-835-4709 or 301-827-1800, or from the Internet at
http://www.fda.gov/cber/guidelines.htm.
For questions on the content of this guidance, contact Division of Human Tissues, Office of
Cellular, Tissue and Gene Therapies at 301-827-6176.
U.S. Department of Health and Human Services
Food and Drug Administration
Center for Biologics Evaluation and Research
April 2008
Contains Nonbinding Recommendations
Table of Contents
I. 	INTRODUCTION............................................................................................................. 1
II. 	BACKGROUND ............................................................................................................... 2
III. 	INVESTIGATION AND CORRECTIVE ACTIONS................................................... 3
IV. 	HCT/P DEVIATION REPORTS FOR DISTRIBUTED HCT/PS............................... 4
A. 	Are These Testing Deficiencies Considered HCT/P Deviations and Do They
Relate to Core Current Good Tissue Practice Requirements?......................... 4
B. 	Am I Required to Report an HCT/P Deviation for the HCT/Ps I Distributed?
................................................................................................................................. 4
C. 	How Should I Report an HCT/P Deviation? ...................................................... 5
D. 	Which Establishment Should Submit the HCT/P Deviation Report? ............. 5
V. 	MITIGATION OF RISK OF HCT/PS IN INVENTORY............................................. 5
A. 	What Should I Do after Quarantining HCT/Ps in Inventory? ......................... 5
B. 	Which Donors Should be Retested and May I Distribute These HCT/Ps? ..... 6
C. 	How Should I Label the HCT/P When I Distribute Them Without Retesting?
................................................................................................................................. 8
i
Contains Nonbinding Recommendations
Guidance for Industry
Certain Human Cells, Tissues, and Cellular and Tissue-Based
Products (HCT/Ps) Recovered from Donors Who
Were Tested For Communicable Diseases Using
Pooled Specimens or Diagnostic Tests
This guidance represents the Food and Drug Administration’s (FDA’s) current thinking on this
topic. It does not create or confer any rights for or on any person and does not operate to bind
FDA or the public. You can use an alternative approach if the approach satisfies the
requirements of the applicable statutes and regulations. If you want to discuss an alternative
approach, contact the appropriate FDA staff. If you cannot identify the appropriate FDA staff,
call the appropriate number listed on the title page of this guidance.
I. 	INTRODUCTION
This guidance provides you, an establishment1 that makes donor eligibility determinations for
certain human cells, tissues, and cellular and tissue-based products (HCT/Ps), with
recommendations concerning the donor eligibility and additional requirements under Title 21
Code of Federal Regulations, Part 1271, Subpart C (21 CFR Part 1271, Subpart C). This
guidance updates and replaces the January 2007 guidance of the same title to:
• 	clarify that for the purposes of this guidance the term “certain HCT/Ps” also includes
certain donor lymphocytes for infusion (DLIs), namely those lymphocytes for infusion
collected from the same donor as hematopoietic progenitor/stem cells (HPCs);
• 	provide updated recommendations regarding donor testing2 using pooled specimens of
HPCs and DLIs (as specified above) due to the approval of Biologics License
Application (BLA) supplements from two nucleic acid test manufacturers (see footnotes
5 through 7); and
• 	specify that this guidance applies to certain HCT/Ps recovered from donors beginning on
or after May 25, 2005 through February 23, 2007.
This guidance addresses certain HCT/Ps that were tested for communicable diseases using
pooled specimens or diagnostic tests. For the purposes of this guidance, certain HCT/Ps means
HPCs, DLIs (as specified above), and reproductive cells and tissues.3 This guidance applies only
1 Under 21 CFR 1271.3(b)(2), an establishment includes facilities that engage in contract manufacturing services for
a manufacturer of HCT/Ps (e.g., laboratories that perform donor testing under contract, agreement, or other
arrangement with an establishment).
2 Donor testing should be performed using the appropriate plasma, serum or blood sample as indicated in the
manufacturer’s instructions. The HCT/Ps are not tested directly.
3 FDA does not include tissues previously subject to regulation under 21 CFR Part 1270 within the category of
“certain HCT/Ps” addressed in this guidance. Instead, we limit the application of this document to certain HCT/Ps
not previously regulated as HCT/Ps.
1
Contains Nonbinding Recommendations
to certain HCT/Ps recovered from donors beginning on or after May 25, 20054 (the effective date
of the regulations contained in 21 CFR Part 1271, Subpart C), through February 23, 2007.5
FDA’s guidance documents, including this guidance, do not establish legally enforceable
responsibilities. Instead, guidances describe the FDA’s current thinking on a topic and should be
viewed only as recommendations, unless specific regulatory or statutory requirements are cited.
The use of the word should in FDA’s guidances means that something is suggested or
recommended, but not required.
II. 	BACKGROUND
FDA’s new donor screening and testing regulations became effective on May 25, 2005
(21 CFR Part 1271, Subpart C). Section 1271.80(c) (21 CFR 1271.80(c)) of those regulations
requires testing establishments to use appropriate FDA-licensed, approved, or cleared donor
screening tests, in accordance with the manufacturer’s instructions, to adequately and
appropriately reduce the risk of transmission of relevant communicable disease agents or
diseases. FDA has learned that some testing laboratories that perform communicable disease
testing on donors of certain HCT/Ps have failed to comply with this provision. This guidance
addresses two categories of compliance problems. Some laboratories, apparently familiar with
pooling instructions for blood and plasma donor specimens, performed Nucleic Acid Testing
(NAT) for human immunodeficiency virus, type 1 (HIV-1) and hepatitis C virus (HCV) on
pooled HCT/P donor specimens, even though the manufacturer’s instructions (package inserts)
for the NAT tests specified that testing be performed on individual HCT/P donor specimens.
Also, some test laboratories used diagnostic tests to test HCT/P donor specimens rather than the
FDA-licensed donor screening tests required by 21 CFR 1271.80(c). Thus, in these two
situations, establishments failed to perform donor testing in accordance with the regulations.
FDA has received inquiries from establishments and professional associations regarding certain
HCT/Ps affected by these testing deficiencies that were distributed or are currently in inventory.
We, FDA, believe that the use of certain HCT/Ps recovered from donors tested in the situations
described above may introduce some additional risk of communicable disease transmission.
When NAT is performed on pooled donor specimens, the sensitivity of the test may not be
comparable to the sensitivity of the test when performed according to the test kit manufacturer’s
instructions. For instance, the HIV-1 and HCV NAT tests have not been established as
adequately sensitive when samples from certain HCT/P donors are tested in pools. Similarly,
some tests cleared or approved by FDA for diagnostic use have not been demonstrated to be as
sensitive as FDA-licensed, approved, or cleared donor screening tests.
FDA has also compared this incremental risk to the costs to patients if these products are
unavailable. For example, patients may die if human leukocyte antigen (HLA) matched HPCs
and DLIs are unavailable. We think that, given the expected benefits of using such HCT/Ps,
under these circumstances, patients may wish to accept the small increased risk presented by
4 69 Federal Register 29785, May 25, 2004; correction 71 Federal Register 14798, March 24, 2006.
5 February 23, 2007, is 30 days after the publication date of the Federal Register notice announcing the availability
of the guidance of the same title, dated January 2007 (72 Federal Register 3149, January 24, 2007).
2
Contains Nonbinding Recommendations
these testing deficiencies, provided the labeling is appropriate and accurately reflects the
increased risk. Accordingly, in this guidance document, we describe ways to help mitigate the
small increased risk presented by these two testing deficiencies. Ways to mitigate include
retesting the donor or justifying why this is not possible, using special labeling for the HCT/P,
and physician notification. With respect to these two categories of testing deficiencies, when the
deficiency occurred soon after the effective date of 21 CFR 1271.80 (see next paragraph), and
when the increased risk is appropriately mitigated (see Section V.), we intend to exercise
enforcement discretion not to prevent distribution of these HCT/Ps.
The recommendations described in this guidance are limited to the two testing deficiencies
described in this guidance; these recommendations do not apply to other failures to comply with
21 CFR 1271.80. Moreover, we intend to exercise our enforcement discretion as described in
this guidance only with respect to certain HCT/Ps recovered from donors beginning on or after
May 25, 2005, through February 23, 2007 (see footnotes 3 and 4). After February 23, 2007, the
agency expects HCT/P establishments and testing laboratories to have corrected their procedures
such that they are in full compliance with testing regulations in 21 CFR 1271.80.
III. 	INVESTIGATION AND CORRECTIVE ACTIONS
Any establishment that performed donor testing subject to one of the two deficiencies described
in this guidance must investigate those deficiencies and ensure that appropriate corrective actions
have been taken to prevent the events described above from occurring again
(21 CFR 1271.160(b)(2) and (3)). If the establishment was a laboratory that performed such
donor testing under a contract, agreement, or other arrangement with another HCT/P
establishment(s), the laboratory must notify the affected HCT/P establishment(s)
(21 CFR 1271.160(b)(2)(ii)). Whether it performed the testing in-house, or contracted with a
laboratory to perform donor testing, the HCT/P establishment(s) must investigate and determine
which distributed HCT/Ps are affected by these testing deficiencies. This includes identification
of affected HCT/Ps that were distributed, and identification of affected HCT/Ps that are in
inventory (21 CFR 1271.160(b)(3)(i)).
Establishments should identify, quarantine, and not distribute HCT/Ps currently in inventory that
were obtained from donors tested using pooled specimens or diagnostic tests. To assure that all
such HCT/P donors are identified:
• 	If donor testing was performed in-house by the HCT/P establishment, that establishment
must investigate to determine which donors were so tested and determine which HCT/Ps
currently in inventory are affected, and quarantine them (21 CFR 1271.160(a) and
1271.65); or
• 	If donor testing was performed by a laboratory under contract, agreement, or other
arrangement, the laboratory must notify the HCT/P establishments affected
(21 CFR 1271.160(b)(2)(ii)) and the HCT/P establishment must investigate and
determine which donors were so tested and which HCT/Ps currently in inventory are
affected and must quarantine affected HCT/Ps (21 CFR 1271.60(a) and 1271.65).
3
Contains Nonbinding Recommendations
IV. 	HCT/P DEVIATION REPORTS FOR DISTRIBUTED HCT/PS
A. 	Are These Testing Deficiencies Considered HCT/P Deviations and Do They
Relate to Core Current Good Tissue Practice Requirements?
FDA defines an HCT/P deviation in 21 CFR 1271.3(dd) as an event:
1. 	That represents a deviation from applicable regulations in 21 CFR Part 1271 or
from applicable standards or established specifications that relate to the
prevention of communicable disease transmission or HCT/P contamination; or
2. 	That is an unexpected or unforeseeable event that may relate to the transmission
or potential transmission of a communicable disease or may lead to HCT/P
contamination.
The testing deficiencies described in this guidance meet the definition of an HCT/P
deviation. Requirements related to donor eligibility determinations, donor screening and
donor testing are core current good tissue practices (CGTPs) (21 CFR 1271.150(b)(10)).
B. 	Am I Required to Report an HCT/P Deviation for the HCT/Ps I Distributed?
Under 21 CFR 1271.350(b)(1), you must investigate all HCT/P deviations related to a
distributed HCT/P for which you performed a manufacturing step. Therefore, the
establishment that performed donor testing must investigate the HCT/P deviations
described in this guidance.
Under 21 CFR 1271.350(b)(2), you must report any such HCT/P deviation relating to a
core CGTP requirement, if the HCT/P deviation occurred in your facility or in a facility
that performed a manufacturing step for you under contract, agreement, or other
arrangement. Since donor testing is a core CGTP, the establishment that distributed the
HCT/P related to a donor testing deficiency must report these HCT/P deviations, as
follows.
1. 	Report an HCT/P deviation for the following distributed HCT/Ps:
• 	HPCs and DLIs derived from peripheral or cord blood:
o 	For use in first-degree or second-degree blood relatives (related
allogeneic). These HCT/Ps are regulated solely under section 361 of the
Public Health Service Act (PHS Act).
2. 	Do not report an HCT/P deviation for the following distributed HCT/Ps:
• 	HPCs and DLIs derived from peripheral or cord blood:
o 	For use in unrelated allogeneic recipients. These HCT/Ps are regulated as
biological products under section 351 of the PHS Act (21 CFR 1271.20).
Section 1271.350 (21 CFR 1271.350) does not apply to HCT/Ps regulated
as biological products (21 CFR 1271.330).
4
Contains Nonbinding Recommendations
ƒ 	If under an Investigational New Drug Application (IND), an
information amendment should be submitted directly to the IND file,
as appropriate (21 CFR 312.31).
o 	For autologous use. No HCT/P deviation report is required because
testing of autologous donors is not required for HCT/Ps regulated under
section 361 of the PHS Act (21 CFR 1271.10).
• 	Reproductive HCT/Ps, because the HCT/P deviation reporting requirements in
21 CFR 1271.350(b) do not apply to reproductive HCT/Ps.
C. 	How Should I Report an HCT/P Deviation?
If an HCT/P deviation report is required for certain distributed HCT/Ps affected by one of
the two testing deficiencies described in this guidance document, you may submit one
HCT/P deviation report for all affected HCT/Ps. HCT/P deviation reports must be
submitted using Form FDA 3486 (Biological Product Deviation Reports) either
electronically as directed on the web at http://www.fda.gov/cber/biodev.biodev.htm or by
mail to the Director, Office of Compliance and Biologics Quality, Center for Biologics
Evaluation and Research (HFM-600), 1401 Rockville Pike, Suite 200N, Rockville, MD
20852-1448 (21 CFR 1271.350(b)(3)). Each report must contain a description of the
HCT/P deviation, information relevant to the event and the manufacture of the HCT/P
involved, and information on all follow-up actions that have been or will be taken in
response to the HCT/P deviation (21 CFR 1271.350(b)(2)).
D. 	Which Establishment Should Submit the HCT/P Deviation Report?
An establishment must report any HCT/P deviation relating to a core CGTP requirement
for distributed HCT/Ps, if the HCT/P deviation occurred in its facility or in a facility that
performed a manufacturing step (e.g., the testing laboratory) for it under contract,
agreement, or other arrangement. Accordingly, the establishment that contracted for the
testing, or that performed the testing in-house on the HCT/P it distributed, must report an
HCT/P deviation (21 CFR 1271.350(b)(2)).
V. 	MITIGATION OF RISK OF HCT/PS IN INVENTORY
A. 	What Should I Do after Quarantining HCT/Ps in Inventory?
If test kits cleared or approved by FDA for diagnostic use were utilized for the original
donor testing, we recommend that when possible, donors should be retested for the
communicable disease agent or disease by using the appropriate FDA-licensed, approved,
or cleared donor screening tests following the manufacturer’s instructions.
5
Contains Nonbinding Recommendations
If pooled NAT testing was performed for the original donor testing, we recommend that
when possible, donors should be retested utilizing the same NAT test, but using an
individual specimen.6
Whenever possible, donor specimens used in retesting should be collected within the
time frame specified in 21 CFR 1271.80(b) (i.e., up to 7 days before or after recovery for
a semen or cord blood stem cell donor, or up to 30 days before recovery for a peripheral
blood stem cell or oocyte donor). If these time frames have already elapsed, you should
still collect and retest a donor specimen from living donors.
B. 	Which Donors Should be Retested and May I Distribute These HCT/Ps?
1. 	HPC and DLI donors (other than autologous)7
• 	If retesting of the retained donor specimen utilizing a licensed donor screening
test is performed in accordance with the manufacturer’s instructions and found
negative or nonreactive, FDA intends to exercise enforcement discretion
regarding distribution of these HCT/Ps. Note that in the case of cord blood
stem cells, the donor to be tested is the birth mother.
• 	If a new specimen is obtained and testing of the donor is performed in
accordance with the manufacturer’s instructions and found negative or
nonreactive, FDA intends to exercise enforcement discretion regarding
distribution of these HCT/Ps.
• 	If retesting of the donor is not feasible (e.g., where a retained specimen is not
available and the donor cannot be located or refuses to be retested), FDA
intends to exercise enforcement discretion regarding the distribution of these
HCT/Ps provided that:
o 	The establishment includes in the accompanying records the reason
retesting could not be performed and maintains this information in its
files;
6 If pooled NAT testing was performed for the original donor testing of HPCs and DLIs, we note that two
manufacturers of FDA-licensed NAT tests, Gen-Probe and Roche Molecular Systems, recently submitted
supplements to their respective BLAs to allow for testing of pooled blood specimens from donors of HPCs and
DLIs. The BLA supplements were recently approved for the following products: Gen-Probe Procleix HIV-1/HCV
Assay (utilizing pools of up to 16), Roche COBAS AmpliScreen HIV-1 Test (utilizing pools of up to 24), and Roche
COBAS AmpliScreen HCV Test (utilizing pools of up to 24). Therefore, if pooled NAT testing was performed for
the original donor testing of HPCs and DLIs, additional labeling or retesting of donors of HPCs and DLIs who had
originally been tested using pooled specimens with the Gen-Probe and Roche NAT tests is not necessary prior to
distribution of these products, provided that records of the testing are reviewed and the testing was performed in
accordance with the current manufacturer’s instructions that now allow pooled specimens (e.g., pool size and assay
procedure are consistent with current instructions). If the original testing was not in accordance with the
manufacturer’s instructions that allow pooled specimens, the HPCs and DLIs should only be distributed consistent
with sections V.B.1 and V.C.
7 Note: Additional labeling or retesting of donors of HPCs and DLIs who had originally been tested using pooled
specimens with the Gen-Probe and Roche NAT tests is not necessary prior to distribution of these products,
provided that records of the testing are reviewed and the testing was performed in accordance with the current
manufacturer’s instructions that now allow pooled specimens (e.g., pool size and assay procedure are consistent with
current instructions) in accordance with section V.A.
6
Contains Nonbinding Recommendations
o 	The establishment documents that the recipient’s physician was notified of
the results of testing and screening, including the labeling provisions
described in section V.C., below; and
o 	The HCT/Ps are labeled in accordance with section V.C., below.
When these inventoried HCT/Ps described above are distributed under this guidance,
we intend to exercise enforcement discretion and do not expect you to submit an
HCT/P deviation report to FDA.
2. 	Reproductive HCT/P donors
Sexually intimate partners who donate gametes for use by the intimate couple are not
required to have donor eligibility determinations (21 CFR 1271.90(a)(2)). However,
directed and anonymous donors of reproductive HCT/Ps are required to be tested
(21 CFR 1271.85(c)).
a. 	Cryopreserved embryos created for sexually intimate partners using a third
party gamete donor
• 	If retesting of the retained donor specimen is performed in accordance
with the manufacturer’s instructions and found to be negative or
nonreactive, FDA intends to exercise enforcement discretion regarding
distribution of these cryopreserved HCT/Ps.
• 	If a new specimen is obtained and testing of the donor is performed in
accordance with the manufacturer’s instructions and found negative or
nonreactive, FDA intends to exercise enforcement discretion regarding
distribution of these HCT/Ps.
• 	If retesting of the donor is not feasible (e.g., where a retained specimen is
not available and the donor cannot be located or refuses to be retested),
FDA intends to exercise enforcement discretion regarding the distribution
of these HCT/Ps provided that:
o 	The establishment includes in the accompanying records the reason
retesting could not be performed and maintains in its files this
information;
o 	The establishment documents that the recipient’s physician was
notified of the results of testing and screening, including the labeling
provisions described in section V.C., below; and
o 	The HCT/Ps are labeled in accordance with section V.C., below.
b. 	Cryopreserved semen or oocytes from anonymous and directed donors
• 	If retesting of the retained donor specimen is performed in accordance
with the manufacturer’s instructions and found to be negative or
nonreactive, FDA intends to exercise enforcement discretion regarding
distribution of these cryopreserved HCT/Ps.
7
Contains Nonbinding Recommendations
• 	If a new specimen is obtained and testing of the donor is performed in
accordance with the manufacturer’s instructions and found negative or
nonreactive, FDA intends to exercise enforcement discretion regarding
distribution of these HCT/Ps.
• 	If retesting is not feasible, FDA does not intend to exercise enforcement
discretion. These HCT/Ps must not be distributed (21 CFR 1271.45(c)
and 1271.50).
When these inventoried HCT/Ps described above are distributed under this
guidance, you do not have to submit an HCT/P deviation report to FDA.
Reproductive HCT/P establishments are not currently subject to
21 CFR 1271.350(b) and are not required to submit HCT/P deviation reports.
C. 	How Should I Label the HCT/P When I Distribute Them Without Retesting?
HCT/Ps from donors that are distributed without retesting should be labeled with the
statement: “WARNING: Advise patient of communicable disease risks.”
If NAT testing was performed on pooled samples,8 not individual samples as specified in
the manufacturer’s instructions, you should list the NAT test and result in the summary of
records and add a qualifier that it was “not performed according to the manufacturer’s
instructions.”
If HCT/P donors were tested using tests cleared or approved by FDA for diagnostic use
rather than FDA-licensed donor screening tests, you should list the diagnostic tests
performed and the result in the summary of records, identifying the tests as “diagnostic
tests used, instead of donor screening tests.”
8 For HPCs and DLIs, if the original pooled NAT testing is not confirmed to have been in accordance with the
manufacturer’s instructions that now allow pooled specimens, you should list the NAT test and result of that test in
the summary of records and add a qualifier that it was “not performed according to the manufacturer’s instructions.”
8

Poursuivez vos recherches dans ChatGPT ou Claude

Connectez Omnilex pour rechercher dans le corpus juridique depuis votre assistant IA.