us-fda-guidance-05d58fed7192335cce034d4c6bc69971•Rheumatoid Arthritis: Developing Drug Products for Treatment
Rheumatoid Arthritis: Developing Drug Products for Treatment
us-fda-guidance-05d58fed7192335cce034d4c6bc69971Rheumatoid Arthritis: Developing Drug Products for TreatmentDraft Guidance
Administrative draft guidance, not enacted legislation. This captured publisher edition preserves the listed document and attachments; later developments are not independently consolidated.
- Docket Number:
- FDA-2013-D-0571
- Issued by:
- Guidance Issuing OfficeCenter for Drug Evaluation and ResearchCenter for Devices and Radiological HealthCenter for Biologics Evaluation and Research
The purpose of this guidance is to outline the FDA’s current thinking on the principles of clinical development relevant to dose-selection and assessment of efficacy and safety to support the approval of drug products for the treatment of patients with rheumatoid arthritis (RA). It also addresses additional considerations for drug products developed as drug-device combination products. This guidance does not address nonclinical development, development of drug products for juvenile idiopathic arthritis, or development of biosimilar products.
Submit Comments
You can submit online or written comments on any guidance at any time (see 21 CFR 10.115(g)(5))
If unable to submit comments online, please mail written comments to:
Dockets Management
Food and Drug Administration
5630 Fishers Lane, Rm 1061
Rockville, MD 20852
All written comments should be identified with this document's docket number: FDA-2013-D-0571.
Guidance for Industry Rheumatoid Arthritis: Developing Drug Products for Treatment DRAFT GUIDANCE This guidance document is being distributed for comment purposes only. Comments and suggestions regarding this draft document should be submitted within 60 days of publication in the Federal Register of the notice announcing the availability of the draft guidance. Submit electronic comments to http://www.regulations.gov. Submit written comments to the Division of Dockets Management (HFA-305), Food and Drug Administration, 5630 Fishers Lane, rm. 1061, Rockville, MD 20852. All comments should be identified with the docket number listed in the notice of availability that publishes in the Federal Register. For questions regarding this draft document contact (CDER) Dr. Nikolay P. Nikolov at 301-796- 2300; (CBER) the Office of Communication, Outreach, and Development at 800-835-4709 or 301-827-1800; or (CDRH) Markham Luke at 301-796-5556. U.S. Department of Health and Human Services Food and Drug Administration Center for Drug Evaluation and Research (CDER) Center for Biologics Evaluation and Research (CBER) Center for Devices and Radiological Health (CDRH) May 2013 Clinical/Medical Revision 1 I:\8932dft.doc 05/13/13
Guidance for Industry Rheumatoid Arthritis: Developing Drug Products for Treatment Additional copies are available from: Office of Communications, Division of Drug Information Center for Drug Evaluation and Research, Food and Drug Administration 10903 New Hampshire Ave., Bldg. 51, rm. 2201, Silver Spring, MD 20993-0002 Tel: 301-796-3400; Fax: 301-847-8714; E-mail: druginfo@fda.hhs.gov http://www.fda.gov/Drugs/GuidanceComplianceRegulatoryInformation/Guidances/default.htm or Office of Communication, Outreach, and Development, HFM-40 Center for Biologics Evaluation and Research, Food and Drug Administration 1401 Rockville Pike, Suite 200N, Rockville, MD 20852-1448 Tel: 800-835-4709 or 301-827-1800; E-mail: ocod@fda.hhs.gov http://www.fda.gov/BiologicsBloodVaccines/GuidanceComplianceRegulatoryInformation/default.htm or Office of Communication, Education, and Radiation Programs Division of Small Manufacturers, International, and Consumer Assistance, HFZ-220 Center for Devices and Radiological Health, Food and Drug Administration 1350 Piccard Drive, Rockville, MD 20850-4307 DSMICA E-mail: dsmica@cdrh.fda.gov; DSMICA Fax: 301-443-8818 (Tel) Manufacturers Assistance: 800-638-2041 or 301-443-6597 (Tel) International Staff: 301-827-3993 http://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/GuidanceDocuments/default.htm U.S. Department of Health and Human Services Food and Drug Administration Center for Drug Evaluation and Research (CDER) Center for Biologics Evaluation and Research (CBER) Center for Devices and Radiological Health (CDRH) May 2013 Clinical/Medical Revision 1
TABLE OF CONTENTS I. INTRODUCTION............................................................................................................. 1 II. CLINICAL DEVELOPMENT PROGRAM .................................................................. 2 A. Dose and Dosing Regimen Selection Considerations...................................................................2 B. Efficacy Considerations .................................................................................................................3 C. Safety Considerations.....................................................................................................................5 D. Drug-Device Combination Product Considerations....................................................................6 REFERENCES.............................................................................................................................. 8
Contains Nonbinding Recommendations Draft — Not for Implementation 1 Guidance for Industry1 2 Rheumatoid Arthritis: 3 Developing Drug Products for Treatment 4 5 6 7 8 This draft guidance, when finalized, will represent the Food and Drug Administration’s (FDA’s) current 9 thinking on this topic. It does not create or confer any rights for or on any person and does not operate to 10 bind FDA or the public. You can use an alternative approach if the approach satisfies the requirements of 11 the applicable statutes and regulations. If you want to discuss an alternative approach, contact the FDA 12 staff responsible for implementing this guidance. If you cannot identify the appropriate FDA staff, call 13 the appropriate number listed on the title page of this guidance. 14 15 16 17 18 I. INTRODUCTION 19 20 The purpose of this guidance is to outline the FDA’s current thinking on the principles of clinical 21 development relevant to dose-selection and assessment of efficacy and safety to support the 22 approval of drug products for the treatment of patients with rheumatoid arthritis (RA). It also 23 addresses additional considerations for drug products developed as drug-device combination 24 products. This guidance does not address nonclinical development, development of drug 25 products for juvenile idiopathic arthritis, or development of biosimilar products. 26 27 This guidance revises the guidance for industry Clinical Development Programs for Drugs, 28 Devices, and Biological Products for the Treatment of Rheumatoid Arthritis (RA), published in 29 February 1999.2 After it has been finalized, this guidance will replace the February 1999 30 guidance and will reflect the current thinking of the FDA on RA drug product development. The 31 FDA’s current thinking has been influenced by clinical development programs conducted for RA 32 since the 1999 guidance published, and by changes in the standard of care for RA because of 33 availability of many effective treatments. The revisions include: 34 35 Dose(s) and dosing regimen(s) selection throughout the clinical development program 36 37 Expectations for establishing efficacy in RA based on signs and symptoms and physical 38 function domains 1 This guidance has been prepared by the Division of Pulmonary, Allergy, and Rheumatology Products in the Center for Drug Evaluation and Research (CDER) in cooperation with the Center for Biologics Evaluation and Research (CBER) and the Center for Devices and Radiological Health (CDRH) at the Food and Drug Administration. 2 We update guidances periodically. To make sure you have the most recent version of a guidance, check the FDA Drugs guidance Web page at http://www.fda.gov/Drugs/GuidanceComplianceRegulatoryInformation/Guidances/default.htm. 1
Contains Nonbinding Recommendations Draft — Not for Implementation 39 40 Use of efficacy endpoints such as clinical remission and prevention of structural damage 41 progression 42 43 Limiting the use of placebo 44 45 Use of active comparator for safety and efficacy trials 46 47 Principles of safety assessment 48 49 Development of drug-device combination products 50 51 This guidance does not discuss general issues of statistical analysis or clinical trial design. Those 52 topics are addressed in the ICH guidances for industry E9 Statistical Principles for Clinical 53 Trials and E10 Choice of Control Group and Related Issues in Clinical Trials, respectively. 54 This guidance focuses on specific drug product development and trial design issues that are 55 unique to the study of RA. 56 57 FDA’s guidance documents, including this guidance, do not establish legally enforceable 58 responsibilities. Instead, guidances describe the Agency’s current thinking on a topic and should 59 be viewed only as recommendations, unless specific regulatory or statutory requirements are 60 cited. The use of the word should in Agency guidances means that something is suggested or 61 recommended, but not required. 62 63 64 II. CLINICAL DEVELOPMENT PROGRAM 65 66 A. Dose and Dosing Regimen Selection Considerations 67 68 The selection of nominal dose(s) and dosing regimen(s) is a fundamental component of drug 69 product development. The recommended dose(s) and dosing regimen(s) should be based on 70 benefit-to-risk assessment and should be supported by all available data gathered throughout the 71 development program. It is important to find the appropriate nominal dose and dosing regimen 72 that produces efficacy with an acceptable long- and short-term safety profile. Many drug 73 products intended to treat RA have the potential to cause serious dose-related adverse reactions, 74 such as opportunistic infections and malignancy, which may not be apparent in short-term 75 clinical trials (see section II.C. for further discussion of the clinical safety database). Dose- 76 ranging exploration should begin early in the development program and often should continue 77 throughout definitive efficacy and safety study(ies). Smaller early dose-ranging exploratory 78 studies may not be adequate for selection of a single dose or a single dosing regimen. 79 80 The following should be considered for the design of dose-ranging studies: 81 82 Studying a wide range of doses and dosing regimens based on pharmacokinetic and 83 relevant pharmacodynamic considerations. 84 2
Contains Nonbinding Recommendations Draft — Not for Implementation 85 Using endpoints sensitive to change to provide better discriminatory power for dose- 86 87 response assessment. A clinical endpoint such as the ACR20 response criteria may not be optimal for this purpose,3 because it is a dichotomous endpoint, and using the 88 89 proportion of responders in a small group of patients could be unreliable. Endpoints such as DAS28, 4 hybrid ACR response,5 and other continuous variables may be more sensitive 90 to change and provide a more suitable alternative to ACR responder index. Supportive 91 pharmacodynamic markers can be considered if scientifically justified. 92 93 Timing of evaluation — assessing at the steep part of the dose-response curve for dose- 94 response assessment. Endpoints should be evaluated at time points before the therapeutic 95 plateau is likely (e.g., weeks 2 through 8) to better capture possible differences between 96 doses. Later time points of evaluation (e.g., 12 weeks) may be informative in estimating 97 clinical effect with chronic use. 98 99 B. Efficacy Considerations 100 101 To meet the regulatory standards for approval under section 505(d) of the Federal Food, Drug, 102 and Cosmetic Act, sponsors must provide substantial evidence of efficacy in the enrolled patient 103 population and demonstrate an acceptable risk-benefit profile for their drug product (21 U.S.C. 104 355(d)). Studying more than one dose/dosing regimen or using an active comparator in 105 definitive studies can facilitate the interpretation of efficacy and the overall risk-benefit 106 evaluation. This section outlines the principles sponsors should follow to assess efficacy of drug 107 products for the treatment of RA. 108 109 1. Establishing efficacy in key RA domains. For marketing approval of drug products for 110 the treatment of RA, sponsors should demonstrate substantial evidence of efficacy in the 111 key RA domains: clinical response and physical function. 112 113 Clinical response. ACR20 response criteria continues to be an accepted measure to 114 demonstrate reduction in RA disease activity. In addition, higher levels of response, 115 as measured by ACR50 and ACR70 response rates, and measures of low disease 116 activity, such as DAS28 less than 2.6, can be used as supportive evidence of efficacy 117 in the clinical response domain. 118 3 ACR20 (50, 70) response criteria — American College of Rheumatology response criteria is a dichotomous composite endpoint indicating the proportion of patients with at least 20 (50, 70) percent improvement in the number of tender and swollen joints, and in three out of the remaining five ACR core-set measures: patient pain, patient global assessment of disease, physician global assessment of disease, physical functioning assessment (Health Assessment Questionnaire-Disability Index (HAQ-DI)), and acute phase reactants. 4 DAS28 — Disease Activity Score 28 is a mathematically calculated, continuous, composite endpoint with differential weighting given to each of the following components: tender joint count (28 joints), swollen joint count (28 joints), acute phase reactant, and patient global assessment of arthritis. 5 Hybrid ACR response is a continuous score of the mean improvement in the core set measures combining the ACR20, ACR50, and ACR70 response rates (American College of Rheumatology Committee to Reevaluate Improvement Criteria 2007). 3
Contains Nonbinding Recommendations Draft — Not for Implementation 119 Physical function. Health Assessment Questionnaire-Disability Index (HAQ-DI) can 120 be used to demonstrate improvement in physical function.6 121 122 Data from 12-week placebo-controlled clinical trial(s) generally would be acceptable to 123 provide evidence of efficacy in clinical response and physical function domains. 124 125 2. Other domains. As noted in item 1 above, for marketing approval in RA, the 126 foundational demonstration of efficacy should include clinical response and physical 127 function using measures such as ACR20 response rates and HAQ-DI, respectively. 128 Demonstration of efficacy in other domains that are important to patients and health care 129 providers can provide further characterization of the efficacy of the drug product and its 130 utility in clinical practice. Other domains can include: 131 132 Prevention of structural damage progression. Reduction in radiographic evidence of 133 structural damage progression is an important predictor of long-term benefits in 134 delaying or preventing the progression to disability related to RA. Radiographic data 135 using validated scoring methods have been used to demonstrate efficacy in this 136 domain. However, demonstration of prevention of structural damage progression on 137 radiographs has become increasingly difficult for several reasons: 138 139 Use of placebo as a control in long-term trials (usually 6 months or longer for 140 trials done in the past to demonstrate effect on radiographic outcomes) is no 141 longer feasible (see item 3 below) 142 143 The extent of progression in the placebo group is low during these short-term 144 trials, and thus the observed treatment effect size of the investigational drug 145 product is small and difficult to detect 146 147 Limitations of the current analysis methods 148 149 Therefore, sponsors should consider alternative study designs (e.g., active comparator 150 studies), applying different measures (e.g., proportions of patients with radiographic 151 progression), and alternative analytical methods when assessing radiographic benefit. 152 Other imaging modalities, such as magnetic resonance imaging and ultrasonography, 153 may allow for demonstration of benefit on structural damage progression in 154 controlled studies that may be shorter than studies using radiographic data. However, 155 these modalities have not been validated as outcome measures in RA to date. 156 157 Clinical remission. Remission is an important goal of RA treatment. The American 158 College of Rheumatology/European League Against Rheumatism (ACR/EULAR) 159 Provisional Definition of Remission criteria may be acceptable for use in RA clinical 160 development programs (ACR/EULAR 2011). Patients who achieve remission should 161 be followed to provide some information on the durability of the remission response. 6 HAQ-DI assesses the degree of difficulty a patient has experienced during the past week in eight domains of daily living activities: dressing and grooming, arising, eating, walking, hygiene, reach, grip, and other activities. 4
Contains Nonbinding Recommendations Draft — Not for Implementation 162 163 Other aspects of RA. Other outcome measures may be informative as additional 164 endpoints in RA clinical development programs. Sponsors should provide supportive 165 evidence on the development of the selected measure. Sponsors also should provide 166 the justification for use of a given measure, which should include importance, clinical 167 relevance, and nonredundancy of the proposed outcome with other measures. 168 169 3. Use of placebo. Assessment of efficacy in some domains may require long-term 170 controlled clinical trial data. However, the availability of effective RA therapies and the 171 shifting paradigm in the treatment of both early and established RA with a focus on early 172 control of disease activity (Singh 2012) have provided a rationale for limiting the 173 exposure of patients to placebo or ineffective therapies for a prolonged period of time 174 (i.e., beyond 12 weeks) (American College of Rheumatology 2011). Therefore, studies 175 longer than 12 weeks should include an active comparator as the control or provisions for 176 escape to rescue treatment for patients with active disease. 177 178 C. Safety Considerations 179 180 The size of the safety database for drugs and biologic products should meet the minimum 181 recommendations outlined in the ICH guidance for industry E1A The Extent of Population 182 Exposure to Assess Clinical Safety: For Drugs Intended for Long-term Treatment of Non-Life- 183 Threatening Conditions. However, drug products developed for RA may have potentially 184 serious adverse effects that may cause concern. Unfortunately, the duration of trials that would 185 support demonstration of efficacy may not be sufficient for an adequate safety assessment 186 because the short duration of a placebo-controlled period (i.e., 12 weeks) would limit the amount 187 of controlled safety data. Therefore, to better characterize the long-term safety profile of the 188 investigational drug product and uncommon adverse events and events with longer latency 189 periods, such as opportunistic infection and malignancy, we may request a premarket safety 190 database of larger size and longer duration than recommended in ICH E1A for new molecular 191 entities intended for the chronic treatment of RA. 192 193 This request will likely include at least 1 year of controlled safety data for a new molecular entity 194 with an active comparator arm to facilitate interpretation of these data. Safety data for a shorter 195 duration may be considered if the drug product is not a new molecular entity. Reasonable 196 comparator arms can include use of multiple doses of the investigational drug product or 197 standard-of-care treatment in definitive clinical trials. Inclusion of more than one dose of 198 investigational drug product can provide important dose-response information with regard to 199 efficacy and safety. For safety issues of interest, sponsors should consider an independent 200 adjudication process. The need for and details of specific monitoring may change as new data 201 emerge. Sponsors are encouraged to discuss their plans for specific safety monitoring with the 202 FDA during the early stages of drug product development. 203 204 The approach to the analyses of safety data should take into account the complexity of the study 205 design (e.g., crossover by response or escape provision, or crossover by design). In addition, the 206 approach to the analyses of integrated safety data should take into account (possible) differing 207 patient populations and/or differing study designs from multiple studies. 5
Contains Nonbinding Recommendations Draft — Not for Implementation 208 209 D. Drug-Device Combination Product Considerations 210 211 Therapies developed for the treatment of RA include drug products that may require parenteral 212 administration and the use of an accessory delivery unit (e.g., an autoinjector). In these cases, 213 the manufacturer of the drug product should ensure that the accessory delivery unit is approved 214 or cleared for marketing through the device regulatory process (e.g., 510(k) process or premarket 215 approval) by the Center for Devices and Radiological Health. If the accessory delivery unit is 216 not already approved or cleared for marketing, then it should be approved or cleared at least 217 concurrently with the drug product approval. 218 219 When the characteristics of the drug product and the delivery device are such that they meet the 220 definition of a combination product under 21 CFR 3.2(e), the center with primary jurisdiction for 221 premarket review and regulation for the combination product will be determined based on the 222 procedure set forth in 21 CFR 3.4. For example, if the primary mode of action of the 223 combination product is that of the drug product, the entire combination product is assigned to the 224 Center for Drug Evaluation and Research. For such combination products, we generally need 225 only one marketing application (e.g., a new drug application/biologics license application). 226 Sponsors are encouraged to contact the Office of Combination Products with general questions 227 regarding drug product jurisdiction and regulatory pathway for their drug-device combination 228 products. 229 230 Generally, each drug-device combination product should have a complete chemistry, 231 manufacturing, and controls database; device design and development; and a substantially 232 complete clinical development program to support efficacy and safety of the entire combination 233 product. We anticipate that the to-be-marketed drug-device combination product will be used in 234 the pivotal studies supporting the efficacy and safety of the combination product for marketing 235 approval. For information on drug-device injector development, see the draft guidance for 236 237 industry and FDA staff Technical Considerations for Pen, Jet, and Related Injectors Intended for Use with Drugs and Biological Products.7 This guidance includes information on issues such as 238 root-cause analyses of device malfunction that may lead to potential improvements to the device 239 240 itself. Likewise, current good manufacturing practice requirements for combination products are provided in 21 CFR part 4, subpart A. 8 241 242 For the development of the RA drug delivery system, sponsors should take into consideration the 243 characteristics of the intended user population and use environment. For products intended for 244 self-administration by an RA patient, the device should be durable, and the dexterity and visual 245 acuity required to use the device should be within the capability of RA patients. Human factor 246 studies to assess use-related hazards should be conducted early in development, ideally before 247 the conduct of key dose-ranging, safety, and efficacy studies. For further considerations on 7 When final, this guidance will represent the FDA’s current thinking on this topic. For the most recent version of a guidance, check the FDA Drugs guidance Web page at http://www.fda.gov/Drugs/GuidanceComplianceRegulatoryInformation/Guidances/default.htm. 8 See https://www.federalregister.gov/articles/2013/01/22/2013-01068/current-good-manufacturing-practice- requirements-for-combination-products. 6
Contains Nonbinding Recommendations Draft — Not for Implementation 248 human factor studies, see the draft guidance for industry and FDA staff Applying Human Factors 249 and Usability Engineering to Optimize Medical Device Design.9 250 251 Ongoing evaluation of device performance should be incorporated into the pivotal studies for the 252 combination product. For example, the evaluation should include asking patients to report 253 devices they perceive to be broken or malfunctioning and to return any such device for 254 evaluation and identification of the problem. Device use and performance also can be evaluated 255 through directed questions defined in the protocols. In addition, a small number of devices (e.g., 256 100) that are apparently functioning normally should be collected after use and evaluated by in 257 vitro performance testing to ensure device robustness. 258 259 Although use of the to-be-marketed formulation and drug-device combination product 260 throughout development is optimal, we acknowledge that changes to the drug product delivery 261 system may occur. Changes in the formulation, excipients, or device components may affect the 262 drug product delivery characteristics and clinical performance of the drug-device combination 263 product. The extent of clinical data needed to support such changes depends on the nature of the 264 change and the development stage. For example, a transition from a prefilled syringe to an 265 autoinjector delivery system involves the following, at a minimum: (1) human factor studies to 266 evaluate potential use-related risks of the modified combination product; (2) a pharmacokinetic 267 bridging study that demonstrates similar delivery of the drug product to the same biospace across 268 a range of body weights; and (3) real-life patient handling experience to assess device 269 performance as discussed above. Depending on the extent of the proposed changes, additional 270 clinical data may be needed to support efficacy and safety, including immunogenicity. 271 272 Sponsors are encouraged to discuss these types of issues and appropriate marketing applications 273 with the FDA as early in development as feasible. 274 9 When final, this guidance will represent the FDA’s current thinking on this topic. For the most recent version of this guidance, check the FDA Device guidance Web page at http://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/GuidanceDocuments/ucm198577.htm. (When final, this guidance will supersede the guidance for industry and FDA premarket and design control reviewers Medical Device Use-Safety: Incorporating Human Factors Engineering into Risk Management. For the most recent version of this guidance, check the FDA Device guidance Web page at http://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/GuidanceDocuments/ucm070271.htm.) 7
Contains Nonbinding Recommendations Draft — Not for Implementation 275 REFERENCES 276 277 Literary 278 279 ACR/EULAR, 2011, Provisional Definition of Remission in Rheumatoid Arthritis for Clinical 280 Trials, Arthritis Rheum., Mar;63(3):573-86. 281 282 American College of Rheumatology, 2011, Clinical Trial Priorities and Design Conference (July 283 22-23, 2010), Arthritis Rheum., Aug;63(8):2151-6. 284 285 American College of Rheumatology Committee to Reevaluate Improvement Criteria, 2007, A 286 Proposed Revision to the ACR20: The Hybrid Measure of American College of Rheumatology 287 Response, Arthritis Rheum., Mar 15;57(2):193-202. 288 289 Singh, JA, 2012, Update of the 2008 American College of Rheumatology Recommendations for 290 the Use of Disease-Modifying Antirheumatic Drugs and Biologic Agents in the Treatment of 291 Rheumatoid Arthritis, Arthritis Care Res., May;64(5):625-39. 292 293 Guidances 294 295 Draft guidance for industry and FDA staff Applying Human Factors and Usability Engineering 296 to Optimize Medical Device Design 297 298 Draft guidance for industry and FDA staff Technical Considerations for Pen, Jet, and Related 299 Injectors Intended for Use with Drugs and Biological Products 300 301 Guidance for industry and FDA premarket and design control reviewers Medical Device Use- 302 Safety: Incorporating Human Factors Engineering into Risk Management 303 304 ICH guidance for industry E1A The Extent of Population Exposure to Assess Clinical Safety: 305 For Drugs Intended for Long-term Treatment of Non-Life-Threatening Conditions 306 8
Ti chiedi come si applica questo testo alla tua situazione?
Consulenza gratuita, senza impegno
Descrivi la tua situazione. Il nostro team ti ricontatterà via e-mail per la tua consulenza.
Continua la tua ricerca in ChatGPT o Claude
Collega Omnilex per cercare nel corpus legale dal tuo assistente IA.